Gys smartmig 142 033153 [16/72] Smartmig

Gys smartmig 142 033153 [16/72] Smartmig
16
SMARTMIG
Translation of the original instructions
EN
CONTROL PANEL (FIG. VI)
Smartmig 142/152/162/182/183 Smartmig 3P
1- Voltage selection button A / B 1- Mode select button MIG/MMA.
2- Voltage selection button min/max. 2- Power adjustment knob MMA or MIG.
3- Wire speed regulator. 3- Wire speed regulator.
4- « SMART » settings table MIG/MAG 4- Voltage selection button A / B
5- Thermal Protection light. 5- « SMART » settings table MIG/MAG & MMA.
6- positions switch 6- Thermal Protection light.
DIRECTIONS OF USE (FIG VI)
MIG/MAG MODE:
SMARTMIG feature allows you to adjust the voltage and the wire speed.
Use the SMART table to nd the correct settings based on the type of wire, and the thickness of the metal workpiece.
Then based on the recommendation indicated, simply select :
• The voltage (buttons A/ B & min/max for SMARTMIG 142, 152 & 162 ; button A/B for SMARTMIG 3P)
• Wire speed - adjust the regulator (3) to the colour zone indicated.
Examples :
To weld 0.8mm thick steel, use 0.6 mm diameter steel wire (SMARTMIG 142, 152 & 162) :
• Move button (1) to the « A » position
• Move button (2) to the « min » position
• Move the regulator (3) to the zone of lightest colour and adjust « by sound » if required
To perform the same operation with SMARTMIG 3P :
• Move button (4) to the « A » position
• Move the regulator (2) to « min » or « max »
• Move the regulator (3) to the zone of lightest colour, and adjust « by sound » if required.
MMA MODE (SMARTMIG 3P ONLY) :
Connect the electrode holder and earth clamp to the machine, respecting the polarity indicated on the electrode pac-
kaging. Then adjust the position.
Example :
For welding metal 4mm thick :
• Move button (1) to the « MMA » position.
• Adjust the regulator (2) to the zone corresponding with electrode diameter 2.5mm.
ADVICE AND THERMAL PROTECTION
• Respect the normal rules of welding
• Leave the machine plugged in after welding to allow it to cool
• Thermal Protection : The LED will illuminate. Cooling will take between 10 and 15 minutes depending on the
ambient temperature.
DUTY CYCLE & WELDING ENVIRONMENT IN USE
• The welding unit describes an output characteristic of «constant current» type. The duty cycles following the stan-
dard EN60974-1 (at 40°C on a 10mn cycle) are indicated in the table here below :
x/60974
@40°C (T
cycle=10min)
142 / 152 162
3P
182 183
MIG/MAG MMA
X%-max 20%-90A 20%-115A 25%-110A 15%-115A 15%-140A 15%-140A
60% 60A 70A 70A 40A 80A 90A
During intensive use (> duty cycle) the thermal protection can activate, if this event the arc switches off and the ther-
mal protection indicator switches on. The welding machine has a constant current output in MIG/MAG. The welding
machine has a constant voltage output in MMA.
Note: the running hot tests have been carried out at atmosphere temperature and duty cycle has been determined at
40°C by simulation.
These are A-class devices. They are designed to be used in an industrial or professional environment. In a different envi-
ronment, it can be difcult to ensure electromagnetic compatibility, due to conducted disturbances as well as radiation.
From 1st December 2010, the new standard EN 60974-10 will be applicable : Warning: these materials do not comply
with IEC 61000-3-12. If they are to be connected to a low-voltage mains supply, it is the responsibility of the user to
ensure they can be connected. If necessary consult the operator of your electrical distribution system.

Содержание