Faber MIRROR WH BRS X/V A80 LOGIC [10/108] En 1 10

Faber MIRROR WH BRS X/V A80 LOGIC [10/108] En 1 10
EN
1
10
Fitting the Hood canopy
Adjust the two screws Vr, in the brackets 11a, so that they are
at the start of their travel (B).
Hook the hood body to the two brackets 11a.
Connect the Hood to the Mains Power Supply, inserting a
bipolar switch with a contact aperture of at least 3mm.
Open the top panel. (See the paragraph on USE)
Open the Bottom Door by pulling it downwards with your
hands.
Remove the Metal Grease Filters using the handles provided.
From the inside of the hood body, turn screws Vr to level the
hood body itself.
Warning: should the rear wall not be completely flat and cause the
two glass panels not to be aligned, pls turn on the two knobs in the
lower part inside the hood body until you reach the perfect alignment of
the two glass panels.
Fasten the safety screw 11.
Replace the Metal Grease Filters, then shut the top panel. (See
the paragraph on USE)
Disconnect the hood from the mains power supply.
Warning: Should the door encounter an obstacle while opening or
closing it will block. When the obstacle is removed and the button is
pressed again the door will open.
Warning: In the event of a malfunction, check the fuse.
(B)
11a
Vr
11
Replacing the fuser
The fuser is placed up on the left side. Turn the fuser holder as
indicated. Replace the fuser with one having the same features.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120mm, the
choice of which is left to the installer.
To install a ø 150 pipe
To install the dumper 10
Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
To install a ø 120 pipe
To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the dumper 10.
Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
Remove any activated charcoal filters.
ø 120