TrustedComputingConguration(AvailablewhenaTPMdevice
is installed and the onboard TPM jumper is enabled)
Security Device Support
If this feature and the TPM jumper on the motherboard are both set to Enabled, onbaord
security devices will be enabled for TPM (Trusted Platform Module) support to enhance data
integrity and network security. Please reboot the system for a change on this setting to take
effect. The options are Disabled and Enabled.
TPM State
This feature changes the TPM State. The options are Disabled and Enabled.
Note: Please reboot the system for the changes on the TPM State to take effect.
Pending TPM operation
Use this item to schedule a TPM-related operation to be performed by a security device for
system data integrity. Your system will reboot to carry out a pending TPM operation. The
options are None and TPM Clear.
Device Select
Use this feature to select the TPM version. TPM 1.2 will restrict support to TPM 1.2 devices.
TPM 2.0 will restrict support for TPM 2.0 devices. Select Auto to enable support for both
versions. The default setting is Auto.
The following are information will be displayed:
• TPM Enabled Status
• TPM Active Status
• TPM Owner Status
TXT Support
Intel TXT (Trusted Execution Technology) helps protect against software-based attacks and
ensures protection, condentiality and integrity of data stored or created on the system. Use
this feature to enable or disable TXT Support. The options are Disabled and Enabled.
iSCSiConguration
iSCSI Initiator Name
This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format.
Once the name of the iSCSI Initiator is entered into the system, congure the proper settings
for the following items.
Add an Attempt
Delete Attempts
Change Attempt order
6.4 Event Logs
This submenu allows the user to congure Event Log settings.
Change SMBIOS Event Log Settings
This feature allows the user to congure SMBIOS Event settings.
Enabling/Disabling Options
SMBIOS Event Log
Select Enabled to enable SMBIOS (System Management BIOS) Event Logging during system
boot. The options are Enabled and Disabled.
Erasing Settings
Erase Event Log
Select Yes to erase all error events in the SMBIOS (System Management BIOS) log before
an event logging is initialized at bootup. The options are No, Yes, Next reset, and Yes, every
reset.
Содержание
377- User s manual
- Superserve
- Chapter 1 introduction
- About this manual
- Table of contents
- Chapter 2 server installation
- Preface
- Chapter 3 maintenance and component installation
- Warnings
- Chapter 6 bios
- Chapter 4 motherboard connections
- Chapter 5 software
- Appendix a bios error codes appendix b standardized warning statements for ac systems appendix c system specifications
- Contacting supermicro
- The following table provides you with an overview of the main features and specifications of the 5019s mn4 please refer to appendix c for additional specifications
- Motherboard
- Hard drives
- Form factor
- Unpacking the system
- Expansion slots
- This chapter provides a brief outline of the functions and features of the 5019s mn4 the 5019s mn4 is based on the x11ssh ln4f motherboard and the sc813mftqc 350cb chassis
- Dimensions
- Description part number quantity
- Systemspecifications
- Decide on a suitable location for the rack unit that will hold the server it should be situated in a clean dust free area that is well ventilated avoid areas where heat electrical noise and electromagnetic fields are generated it will also require a grounded ac power outlet nearby be sure to read the precautions and considerations noted in appendix b
- System specifications
- Chipset
- Superserver 5019s mn4 user s manual chapter 1 introduction
- Chassis
- Socket type
- Chapter 1 introduction
- Overview
- Chapter 1
- Memory
- Main parts list
- Introduction
- Inspect the box the superserver 5019s mn4 was shipped in and note if it was damaged in any way if any equipment appears damaged please file a damage claim with the carrier who delivered it
- In additon to the motherboard and chassis several important parts that are included with the system are listed below
- Control panel features
- Control panel
- 7 6 5 4 3 2
- The switches and leds located on the control panel are described below see chapter 4 for more details on the control panel
- The sc813mftqc 350cb is a mini 1u chassis see the illustration below for the features included on the front of the chassis
- Superserver 5019s mn4 user s manual chapter 1 introduction
- Server chassis features
- Item feature description
- Front features
- Front chassis features
- Figure 1 2 chassis front view
- Figure 1 1 control panel view
- Rear chassis features
- Motherboard layout
- Item feature description
- Figure 1 4 motherboard layout
- Figure 1 3 chassis rear view
- Below is a layout of the x11ssh ln4f with jumper connector and led locations shown see the table on the following pages for descriptions for detailed descriptions pinout information and jumper settings refer to chapter 4
- The illustration below shows the features included on the rear of the chassis
- Superserver 5019s mn4 user s manual chapter 1 introduction
- Rear features
- Superserver 5019s mn4 user s manual chapter 1 introduction
- Quick reference table
- Led description status
- Jumper description default setting
- Connector description
- Preparing for setup
- Overview
- Mechanical loading
- Choosing a setup location
- Chapter 2 server installation
- Chapter 2
- Ambient operating temperature
- Airflow
- Server precautions
- Server installation
- Rack precautions
- Rack mounting considerations
- Reliable ground
- Installing the rails
- Installing the chassis rails
- Identifying the rails
- Circuit overloading
- Installing the server into a rack
- Installing the rack rails
- Installing the server into a telco rack
- Maintenance and component installation
- Chapter 3 maintenance and component installation
- Chapter 3
- Accessing the system
- Removing power
- Processor and heatsink installation
- Motherboard components
- Pci expansion card installation
- Memory support
- Memory installation
- Dimm module population sequence
- Motherboard battery
- Hard drives
- Chassis components
- System cooling
- Installing fans
- Hard drive carrier indicators
- Power supply failure
- Power supply
- Air shroud
- Processor power connector
- Power supply smbus header
- Power connections
- Please review the safety precautions in chapter 3 before installing or removing components
- Pin processor power jpwr2
- Pin primary atx power jpwr1
- Motherboard connections
- Main atx power connector
- Jpwr2 must also be connected to the power supply this connector is used to power the processor s
- Important to provide adequate power to the motherboard connect the 24 pin and the 8 pin power connectors to the power supply failure to do so may void the manufacturer s warranty on your power supply and motherboard
- Headers and connectors
- Fan headers
- Two power connections on the x11ssh ln4f must be connected to the power supply the wiring is included with the power supply
- Chapter 4 motherboard connections superserver 5019s mn4 user s manual
- This section describes the connections on the motherboard and provides pinout definitions note that depending on how the system is configured not all connections are required the leds on the motherboard are also described here a severboard layout indicating component locations may be found in appendix b
- Chapter 4 motherboard connections
- There are five fan headers on the motherboard these are 4 pin fan headers pins 1 3 are backward compatible with traditional 3 pin fans the onboard fan speeds are controlled by thermal management via ipmi when using thermal management setting please use all 3 pin fans or all 4 pin fans
- Chapter 4
- The primary power connector jpwr1 meets the atx ssi eps 12v specification you must also connect the 8 pin jpwr2 processor power connector to your power supply see below
- A power smb header is located at pw4 connect the appropriate cable here to utilize smb on your system
- Tpm port 80 header
- The standby power header is located at jstby1 on the motherboard
- The sgpio serial general purpose input output headers are used to communicate with the enclosure management chip on the backplane and support the sata ports
- The internal speaker sp1 can be used to provide audible notifications using various beep codes
- Standby power
- Sgpio headers
- Power led speaker
- Pins 1 3 of jd1 are used for power led indication and pins 4 7 are for the speaker please note that the speaker connector pins 4 7 are used with an external speaker if you wish to use the onboard speaker you should close pins 6 7 with a jumper
- Internal speaker buzzer
- Disk on module power connector
- Chapter 4 motherboard connections superserver 5019s mn4 user s manual
- A trusted platform module tpm port 80 header is located at jtpm1 to provide tpm support and port 80 connection use this header to enhance system performance and data security
- Two power connectors for sata dom disk on module devices are located at jsd1 jsd2 connect appropriate cables here to provide power support for your serial link dom devices
- The joh1 header is used to connect an led indicator to provide warnings of chassis overheating and fan failure this led will blink when a fan failure occurs
- Power smb
- Pin bmc external
- Overheat fan fail led header
- Note uid can also be triggered via ipmi on the motherboard for more information on ipmi please refer to the ipmi user s guide posted on our website at http www supermicro com
- M slot
- Chassis intrusion
- Chapter 4 motherboard connections superserver 5019s mn4 user s manual
- C1 monitors the power supply fan and system temperatures
- C header
- C connector jp
- C connection on your system
- Unitidentifierswitch uidledindicator
- A system management bus header for ipmi 2 is located at jipmb1 connect the appropriate cable here to use the ipmb
- The x11ssh ln4f contains one m socket at j23 m was formerly next generation form factor ngff and serves to replace mini pci e and msata m allows for a greater variety of card sizes increased functionality and spatial efficiency
- A rear unit identifier uid switch and a rear uid led led1 are located next to the vga port on the motherboard the front uid switch and the front uid led are both located on the front panel control jf1 with the front uid switch on pin 13 and the front led on pin 7 of jf1 when you press the front or the rear uid switch both front and rear uid leds will be turned on press the uid switch again to turn off the led indicators the uid indicators provide easy identification of a system unit that may be in need of service
- A chassis intrusion header is located at jl1 on the motherboard attach the appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened
- The power system management bus
- The m socket on the x11ssh ln4f motherboard supports pci e 3 x2 m cards in the 22x80mm form factor
- The power fail led connection is located on pins 5 and 6 of jf1
- The power button connection is located on pins 1 and 2 of jf1 momentarily contacting both pins will power on off the system this button can also be configured to function as a suspend button with a setting in the bios see chapter 7 to turn off the power when the system is in suspend mode press the button for 4 seconds or longer
- Reset button
- Power fail led
- Power button
- Overheat oh fan fail
- Jf1 contains header pins for various control panel connections see the figure below for the pin locations and definitions of the control panel buttons and led indicators
- Figure 4 1 jf1 control panel pins
- Control panel
- Connect an led cable to pins 7 and 8 of jf1 to use the overheat fan fail led connections the led on pin 8 provides warnings of overheat or fan failure
- Chapter 4 motherboard connections superserver 5019s mn4 user s manual
- All jf1 wires have been bundled into a single cable to simplify this connection make sure the red wire plugs into pin 1 as marked on the motherboard the other end connects to the control panel pcb board
- The reset button connection is located on pins 3 and 4 of jf1 attach it to a hardware reset switch on the computer case
- The hdd led uid switch connection is located on pins 13 and 14 of jf1 attach a cable to pin 14 to show hard drive activity status attach a cable to pin 13 to use uid switch refer to the table below for pin definitions
- The power led connection is located on pins 15 and 16 of jf1
- The non maskable interrupt button header is located on pins 19 and 20 of jf1
- The nic network interface controller led connection for lan port 1 is located on pins 11 and 12 of jf1 and the led connection for lan port 2 is on pins 9 and 10 attach the nic led cables here to display network activity
- The data cables in the system have been carefully routed to maintain airflow efficiency if you disconnect any of these cables take care to re route them as they were originally when reconnecting them
- Power led
- Power cables
- Pin processor power jpwr2
- Pin primary atx power jpwr1
- Nmi button
- Nic1 nic2 lan1 lan2
- Important make sure the the cables do not come into contact with the fans
- Hdd led uid switch
- Data cables
- Chapter 4 motherboard connections superserver 5019s mn4 user s manual
- Three power connections on the x11ssh ln4f must be connected to the power supply the wiring is included with the power supply
- Two com ports com1 com2 are located on the motherboard com1 is a port located on the i o back panel com2 is a header located next to com1
- Universal serial bus usb ports
- There are two usb 2 ports usb 0 1 and two usb 3 ports usb 6 7 located on the rear i o panel the x11ssh ln4f also has two front access usb 2 headers usb2 3 and usb4 5 and one front access usb 3 header usb8 9 usb10 is a type a 3 header the onboard headers can be used to provide front side usb access with a cable not included
- The x11ssh ln4f includes a total of eight sata ports supported by the intel c236 pch chip these sata ports support raid 0 1 5 and 10
- Serial ports
- See the figure below for the locations and descriptions of the various i o ports on the rear of the motherboard
- Sata ports
- Rear i o ports
- Notes i sata0 and i sata1 are supermicro superdoms these are yellow satadom ports with power pins built in and do not require separate external power cables these ports are backward compatible with non supermicro satadoms that do require external power
- For more information on the sata hostraid configuration please refer to the intel sata hostraid user s guide posted on our website at http www supermicro com
- Figure 4 2 rear i o ports
- Description description description
- Chapter 4 motherboard connections superserver 5019s mn4 user s manual
- Jumpers
- Explanation of jumpers
- Use jumpers j
- Use jumper jbr1 to recover the bios settings on the motherboard the default setting is normal
- Smbus to pci slots
- Note when watch dog is enabled the user needs to write their own application software to disable it
- Manufacturer mode select
- Lan1 2 enable disable
- Jwd controls the watch dog function watch dog is a monitor that can reboot the system when a software application hangs jumping pins 1 2 will cause watch dog to reset the system if an application hangs jumping pins 2 3 will generate a non maskable interrupt signal for the application that hangs watch dog must also be enabled in bios the default setting is reset
- Jumper jpb1 allows you to enable the embedded aspeed ast2400 baseboard management controller bmc to provide ipmi 2 kvm support on the motherboard the default setting is bmc enable
- Jpg1 allows you to enable or disable the vga port the default setting is enabled
- Close pins 2 and 3 of jumper jpme2 to bypass spi flash security and force the system to operate in the manufacturer mode which will allow the user to flash the system firmware from a host server for system setting modifications the default setting is normal
- Chapter 4 motherboard connections superserver 5019s mn4 user s manual
- Change the setting of jumper jpl1 and jpl2 to enable or disable the lan1 and lan2 ethernets ports respectively the default setting is enabled
- C2 to connect the system management bus i2c to pci express slots to improve pci performance these two jumpers should be set to the same setting the default setting is disabled
- C1 and j
- Bmc enabled
- Watch dog
- Bios recovery
- Vga enable disable
- The onboard power led is located at ledpwr when this led is on the system is on be sure to turn off the system and unplug the power cord before removing or installing components
- The front panel nic network interface connection activity led indicators for lan3 lan4 are located at j7 j8
- Server connections
- Onboard power led
- Led indicators
- Lan3 lan4 front panel activity leds
- Lan leds
- Dedicated ipmi lan leds
- Control panel
- Chapter 4 motherboard connections superserver 5019s mn4 user s manual
- Bmc heartbeat led
- An m led is located at le3 on the motherboard when le3 is blinking m is functioning normally
- An ipmi lan is also located on the rear i o panel the led on the right indicates activity while the led on the left indicates the speed of the connection
- A bmc heartbeat led is located at ledbmc on the motherboard when ledbmc is blinking the bmc is functioning normally
- Two lan ports are located on the rear i o panel of the motherboard each ethernet lan port has two leds the green led indicates activity while the other link led may be green amber or off to indicate the speed of the connection
- Software
- Rear i o ports
- Power cables
- Os installation
- Installing windows to a non raid system
- Installing the windows os for a raid system
- Driver installation
- Data cables
- Chapter 5 software
- Chapter 5
- Superdoctor 5
- Superdocto
- Sas sata drives
- Peripheral drives
- Dvd rom drive optional
- Starting the setup utility
- Main setup
- Introduction
- Howtochangetheconfigurationdata
- How to change the configuration data
- Chapter 6 bios
- Chapter 6
- Boot feature
- Advancedsetupconfigurations
- Advanced setup configurations
- Powerconfiguration
- Cpuconfiguration
- Graphicsconfiguration
- Dmi opiconfiguration
- Cputhermalconfiguration
- Chipsetconfiguration
- Systemagent sa configuration
- Primary peg pci express graphics
- Primary pcie pci express graphics
- Slot6 power limit value
- Slot6 power limit scale
- Slot6 max link speed
- Program pcie aspm after oprom
- Pegportconfiguration
- Memoryconfiguration
- Sataconfiguration
- Pciexpressconfiguration
- Pch slot4 pci e 3 x4 in x8
- Pch ioconfiguration
- Gt power management control
- Pcie pci pnpconfiguration
- Superioconfiguration
- Serial port console redirection
- Intel server platform services
- Com1 console redirection settings
- Sol com2 console redirection settings
- Ems console redirection settings
- Acpi settings
- Trustedcomputingconfiguration availablewhenatpmdevice is installed and the onboard tpm jumper is enabled
- Iscsiconfiguration
- Event logs
- Delete attempts
- Change smbios event log settings
- Change attempt order
- Add an attempt
- View smbios event log
- System event log
- Bmcnetworkconfiguration
- Security
- Secure boot menu
- Save all secure boot variables
- Platform key pk size key key source
- Key management
- Key exchange keys size key key source
- Forbidden signatures size key key source
- Enroll all factory default keys
- Bootconfiguration
- Boot settings
- Authorized timestamps size key key source
- Authorized signatures size key key source
- Save exit
- Appendix a
- A 2 additional bios post codes
- A 1 bios error beep post codes
- Bios error codes
- Appendix a bios error codes
- ןונקת תורהצהאהרהז ןה תואבה תורהצהא ינפמ שמתשמה תא ריהזהל תנמ לע היישעתה ינקת יפ לע תורהז הלבח ה וא תולאש שיו הדימב תירשפא תיזיפי יהשלכ היעבב תולקתרוציל שי הכימת תקלחמ םע רשק רידגהל וא ןיקתהל םיאשר דבלב םיכמסומ םיאנכט ורקימרפוס לש תינכט תאה םיביכר אורקל שי ורקימרפוס יזראמב םיביכרה תרדגה וא תנקתה ינפל ואולמב חפסנה תא
- Warningdefinition
- Systems
- Standardized warning statements for ac
- B about standardized warning statements
- Appendix b standardized warning statements for ac systems
- Appendix b
- لا تاداشرإ رقابيكرت ليصوت لبق ىلإ ماظنلا ةقاطلل ردصم
- ف ك ا ىأ يكو ةلاح ف ببستت ةباصا ة ذسج زهزلا اذه ع زطخ ز ذحت ىأ لبق يأ ىلع لوعت تاذعه كنلع ىلع ي يع ةوجا لا زطاخولاب زئاوذلا ة ئابزهكلا كوة ارد ىلع ي راوولابتاس ة ئاقىلا ل ع وعىقو يأثداىح نقر مذختسا ىا بلا صىص ولا ة اه ف ز ذحت لك رىثعلل اهتوجزت
- אורקל שי רוקמל תכרעמה רוביח ינפל הנקתה תוארוה תאחתמ
- متيتلا
- زاهجل
- ילמשח קותינ ינפמ הרהזא
- Power disconnection warning
- يئاقول
- ىلع
- هيبردملاو و بيكزتللادبتسا وأ ةمدخ ساهجلا اذه حمسي نأ بجي طقف هيلهؤملا هيفظىملل
- مصف بجي واظننا عيمج نمرداصم تقاطنا تنازإو ءابرهكنا كهس نم ةدحو دادما تقاطنا مبق ىنإ لىصىنا تيهخادنا قطانمنا نمكيهه تنازإ وأ جيبثتن ثانىكم زاهجلا
- הרהזא שר דבלב ךמסומ תווצתא ףילחהל ןיקתהל יא דויצה רובע תוריש תתל וא דויצה
- Restricted area
- Equipment installation
- صيصخت ةذحىنا هذه ف اهب كرتن قطانم ةروظحم مت صىنا نكم نإ لى تقطنم ةروظحم طقف واذختسا للاخ نم تصاخ ةادأ وأ أ لان يرخأ ته سو املأم حاتفمو مفق
- תלבגומ השיג םע רוזא הרהזא תרזעב תנתינ השיגה השיג תלבגה םהב שיש םירוזאב הדיחיה תא ןיקתהל שי דכו לוענמ חתפמ דבלב החטבא ילכ
- הרהזא תנכס תמייקץוציפ הניקת אל ךרדב הפלחוהו הדימב הללוסה לש ףילחהל שי גוסב הללוסה תא מ םאותה תרבחלמומ ןרציתצ תוללוסה קוליס תושמושמה עצבל שי ןרציה תוארוה יפל
- رطخ كانه نم لاذبحسا ةلاح يف راجفنا ةيراطبلا ةحيحص ريغ ةقيرطب ليلعف ةيراطبلا لاذبحسا طقف عىنلا سفنب اهلداعي ام وأ اممثصوأ ةعنصملا ةمرشلا هب تايراطبلا نم صلخج ل اقفو ةلمعحسملاةعناصلا ةمرشلا تاميلعح
- دق اذهل نوكي لازاهج تلااصتا ةدع تادحوب ةقاطلا دادما ةلازإ بجي تلااصتلاا ةفاك لسعل لاةدحو نع ءابرهكلا
- דחא קפסמ רתוי םייק םא הרהזא קפס לש דחא רוביחמ רתוי שי הדחיל תא ריסהל שי ןקורל תנמ לע םירוביחה לכ חיה תאי הד
- Redundant power supplies
- Comply with local and national electrical codes
- Backplane voltage
- كانه زطخ هم يئابزهكلا رايتلا ىلع ةدىجىملا ةقاطلاوأ ةحىللا نىكي امدنعماظنلا لمعي دنع ارذح هك ةمدخ ساهجلا اذه
- ירוחאה לנפב חתמ זא הרה ךלהמב רהזיהל שי תכרעמה לועפת ןמזב ירוחאה לנפב חתמ תנכס תמייק הדובעה
- تادعملا بيكرت ةيئابرهكلا لل لثتمي نأ بجي هيواىقةيىطىلاو ةيلحملا ةقلعتملا ءابرهكلاب
- רצומה קוליס הרהזא ו תויחנהל םאתהב תויהל בייח הז רצומ לש יפוס קוליס הנידמה יקוח
- יצראה למשחה יקוח םואית הרהזא תנקתה םייצראהו םיימוקמה למשחה יקוחל תמאות תויהל תבייח דויצה
- Product disposal
- Hot swap fan warning
- هكممنا هم حوارمنا نأ لاست لا ةنازإ دنعرودت ةهتك ةحورمنا مكيهنا هم بجي ءاقبإ عباصلأا ويغاربنا تاكفم ءايشلأا هم اهريغو اديعب هع تاحتفنا يف ةهتك ةحورمنا
- הרהזא יקלח תא םיריסמ רשאכ שי םידבוע ןיידע םיררוואמהו ןכתי זראמהמ ררוואמה קיחרהללררוואמה ךותב םיחתפהמ םינוש הדובע ילכו תועבצאה תא חוטב קחרמ
- Power cable and ac adapter
- רשא וא הלקתל םורגל לוכי רחא םאתמ וא לבכ לכב שומיש ךכ םשל וקפוסו ודעונ טב יקוחו למשח ירישכמב שומיש יקוח יפ לע ילמשח רצק רוסיא םייק תוחי ב םיכמסומה םילבכב שמתשהל
- רחא ילמשח רצומ לכ רובע דבלב ורקימקרפוס ידי לע ןיוצ אלש
- לש דוק םהילע עיפומ ראשכ
- הרהזא םימאתמו םיקפס םילבכב שמתשהל שי רצומה תא םיניקתמ רשאכ
- ב וא
- אתמו םיילמשחמ י
- System cooling
- Superserver 5019s mn4 user s manual
- Sata controller
- Regulatory compliance
- Processors
- Power supply
- Perchlorate warning
- Pci expansion slots
- Operating environment
- Motherboard
- Memory
- Drive bays
- Chipset
- Chassis
- Appendix c system specifications
- Systemspecifications
- Appendix c
Похожие устройства
-
Supermicro SYS-7047GR-TRF, X9DRG-QF C602 Dual Xeon Socket2011 1866/1600/1333/1066/800MHz, up to 192GB DDR3 ECC Reg, 10xSATA, 1620WИнструкция по эксплуатации -
Supermicro SYS-7048R-TR, X10DRi C612 Dual Xeon Socket2011-3 2133/1866/1600MHz, up to 1TB DDR4 ECC Reg, 8xSATA3, 920W (1+1)Инструкция по эксплуатации -
Supermicro SYS-7048R-TRT, X10DRi-T C612 Dual Xeon Socket2011-3 2133/1866/1600MHz, up to 1TB DDR4 ECC Reg, 8xSATA3, 920W (1+1)Инструкция по эксплуатации -
Supermicro SYS-7047R-TRF, X9DRi-F C602 Dual Xeon Socket2011, 800-1600MHz, up to 512MB DDR3 ECC Reg, 8xSATA3, 920W (1+1)Инструкция по эксплуатации -
Supermicro SYS-5018R-МRИнструкция по эксплуатации -
Supermicro SYS-1028R-WC1RTИнструкция по эксплуатации -
Supermicro SYS-1028R-WC1RИнструкция по эксплуатации -
Supermicro SYS-1018GR-TИнструкция по эксплуатации -
Supermicro SYS-5018A-TN4Инструкция по эксплуатации -
Supermicro SYS-6028R-TRTИнструкция по эксплуатации -
Supermicro sys-6028r-trИнструкция по эксплуатации -
Supermicro sys-5018d-mtrfИнструкция по эксплуатации
Изучите настройки BIOS, включая поддержку TPM и конфигурацию iSCSI, для улучшения безопасности данных и управления системой. Узнайте, как активировать функции защиты.