30
Press the button once (> 2 seconds) until the total
capacity (at 0% bypass) and the current date appear.
> 2 sec
The set parameters have been accepted.
Note: If no input is made within 30 seconds, the display will return to standby or operating mode
without accepting amended parameters.
Insert the display unit from the front at a height of approx. 10 mm and slide down. The loops on
the display part must be inserted in the grooves on the measuring head. Continue with Chapter
5.4 Flushing/Draining for Filter Systems with and without Measuring and Display Unit.
5.3 By-pass setting
Determining the by-pass setting
The by-pass setting is identi ed according to the application and the carbonate hardness or total
hardness identifi ed on the basis of the bypass and capacity table (Chapter 7). The by-pass is then
set on the by-pass screw
19
as follows:
Turn the by-pass screw
19
until the desired by-pass (050 %) agrees with the marking.
!
Caution: Use Allen key 6mm or 7/32".
!
Caution: Never overwind the by-pass screw to avoid any damage.
5.4 Flushing/Bleeding Filter Systems with and without Measuring and Display Unit
Note: A 10 litre bucket is required for fl ushing/draining.
Position fi lter system horizontally.
Completely open fl ush valve
9
.
Open the inlet valve
7
at inlet hose
6
while holding the fl ush hose in the
bucket. Flush quantity at least 10 litres with a minimum volumetric fl ow of 3 l/
min (180 l/h).
Close fl ush valve
9
, put down fi lter and empty bucket.
Carefully open fl ush valve
9
while holding the fl ush hose in the bucket. Flush
quantity once again at least 10 litres.
Close fl ush valve
9
.
Check system for any leaks.