35
Total hardness
measured
°dH
By-pass setting
PURITY
Finest 600
PURITY
Finest 1200
27 0 % 1630 3019
28 0 % 1571 2911
29 0 % 1517 2810
30 0 % 1467 2717
31 0 % 1419 2629
32 0 % 1375 2547
33 0 % 1333 2470
34 0 % 129 4 2397
35 0 % 1257 2329
8 Repair
Regularly check the fi lter system for leaks. Regularly check the hoses for kinks. Bent hoses must be
replaced.
The complete fi lter system must be replaced in rotation after a maximum of ten years.
The hoses must be replaced in rotation after a maximum of fi ve years.
!
Caution: Prior to changing, read the Technical Data (Chapter 12) and the Operating and Safety
Information (Chapter 3).
Regularly clean the outside of the fi lter system with a soft, damp cloth.
!
Caution: Do not use any substances incompatible with the material (Chapter 3.4) or abrasive
cleaning materials.
9 Query Mode
The following data can be queried in the query mode:
Production data
Briefl y press button 1 x (< 1 second), the following message appears.
Serial Appliance Number Battery Service Life
ID Level Production Year
Production year: Example 08 = 2008
Device number: consecutive
Battery useful life: Example 31/12/19 = The battery in the display unit will be exhausted on 31/12/19
and the complete fi lter system has reached its max. usage period.