32
If this button is pressed (> 10 seconds), the data
set on initial installation will be accepted again, and
the capacity, by-pass setting and input date are all
updated.
> 10 sec
Note: This automatically sets the monthly limit to 12 months.
Note: If no input is made within 30 seconds, the display will return to operating mode without
accepting amended parameters.
Insert display unit from front at a height of approx. 10 mm and slide down. The loops on the display
part must be inserted in the grooves on the measuring head.
6.1 Removing the Filter Cartridge
Switch off power supply to the terminal device (remove plug).
Close inlet valve
7
at inlet hose
6
.
Place the fl ushing hose in a bucket and remove pressure from the fi lter system by opening the
ush valve. Catch the escaping water in a bucket.
Note: If the escaping water is more than 1 litre, the inlet valve
7
is not completely closed or is
blocked with scale.
Stand on the kick loops
12
with both feet while opening the pressure vessel
lid
3
by pressing the lock
15
and turning it anticlockwise as far as it will go.
Place the pressure vessel lid
3
vertically on both lid handles
20
.
Note: Do not turn the lid horizontally on its head.
Stand on the kick loops
12
with both feet while turning the pressure vessel
1
anticlockwise by
the mantle handles
16
as far as it will go.
Take your feet off the kick loops
12
and press the pressure vessel
1
down with both hands on
the mantle handles
16
.
Remove exhausted fi lter cartridge
2
from the pressure vessel
1
.
Place the exhausted fi lter cartridge
2
in the sink with the connection facing down to drain the
remaining water (> 5 min.).
Lock the exhausted fi lter cartridge
2
with the transport protective cap
18
of the new fi lter
cartridge and return in the original packaging to the appropriate BRITA address listed on the
back of the cover.
6.2 Inserting the Filter Cartridge
Check that the O-ring seal of the fi lter cartridge
2
is correctly seated in the
groove and also check for dirt and damage.
Note: The cartridge seat has been lubricated with food-safe lubricant at the
factory.
Check the connector seat of the fi lter cartridge O-ring
2
in the pressure vessel
lid
1
for dirt and damage.
Place the new fi lter cartridge
2
in the pressure vessel
1
.
Stand on the kick loops
12
with both feet, lift the pressure vessel
1
turning it
clockwise until the mantle handle
16
is over the kick loops
12
.