SECONDARY AIR
Adjustment is carried out with the same lever for primary air. Secondary air is released proportionally to primary air in a pre-calculated
balance that the user can never change incurring in wrong adjustments. One will thus not have combustion excesses. Secondary air
allows the combustion process to be completed and enhances eciency. In the left position (Min) one decreases the amount of air in the
combustion chamber where i.e. only a minimum amount of primary and secondary air is present.
This position is used to prolong combustion (for instance, at night, or when you are not at home) so that the stove is set to minimum for
auto-combustion, to save on fuel and keep the ame burning.
The use of humid or treated wood releases a greater amount of smoke than usual, which could dirty the glass more
quickly. The poor performance of the ue pipe can also compromise the cleanliness of the glass, considering that the
smoke remains in the combustion chamber longer than usual.
DOOR OPENING SWITCH
On closed replaces there is a switch installed by MCZ and in the case of forced ventilation, it turns o the fans when the door of the closed
replace is open (see the relative manual for the basic-slim comfort air kit).
QUICK RESPONSE
If for any reason one needs to extinguish the re in the stove suddenly and quickly or put out a re that has started in the ue pipe, act
as follows:
• Time permitting, remove the embers and ashes using a metal container.
• Request immediate help from the relative organisations.
Содержание
- Care of the manual and how to consult it 3
- Introduction 3
- Revisions to the publication 3
- Symbols used in the manual 3
- Safety precautions 4
- Warnings and warranty conditions 4
- Information 5
- Intended use 5
- Warnings and warranty conditions 5
- Warranty conditions 5
- Exclusions 6
- Warnings and warranty conditions 6
- Spare parts 7
- Warnings and warranty conditions 7
- Warnings for the correct disposal of the product 7
- Installation 9
- Installation foreword 9
- Minimum distances 9
- Foreword 10
- Min 5 metri 10
- Smoke flue 10
- Technical characteristics 11
- Dimensioning 12
- Chimney 13
- Chimney components 13
- Maintenance 13
- External air inlet 14
- Connection to flue 15
- Examples of correct installation 17
- Dimensions and technical characteristics 18
- Forma wood 75 dx sx dimensions sx left version in figure 18
- Dimensions and technical characteristics 19
- Forma wood 95 dx sx dimensions sx left version in figure 19
- Technical dept all rights reserved reproduction is prohibited 19
- Dimensions and technical characteristics 20
- Forma wood t95 dimensions 20
- Dimensions and technical characteristics 21
- Forma wood t50 dimensions 21
- Technical dept all rights reserved reproduction is prohibited 21
- Dimensions and technical characteristics 22
- Technical characteristics 22
- Installation and assembly 23
- Preparation and unpacking 23
- Choice of operating mode 24
- Counterweights unlocking 24
- Forced convection comfort air vf 24
- Installation and assembly 24
- Natural convection comfort air vn 24
- Installation and assembly 25
- Positioning 25
- Height and level adjustment 26
- Installation and assembly 26
- Combustion air inlet 27
- External and internal air inlet 27
- Forced ventilation air inlet 27
- Installation and assembly 27
- Natural ventilation air inlet 27
- Cladding and counter hood assembly 28
- Flue connection 28
- Installation and assembly 28
- Fireplace insulation 29
- Hood ventilation outlets 29
- Installation and assembly 29
- Wooden beam insulation 29
- Do not expect heating efficiency immediately 30
- Operation 30
- Operation test 30
- Start up precautions 30
- Fuel wood 31
- Operation 31
- Stages for the first start up test 31
- First ignition 32
- Operation 32
- Fuel loading 33
- Operation 33
- Combustion control 34
- Operation 34
- Primary air 34
- Door opening switch 35
- Operation 35
- Quick response 35
- Secondary air 35
- Cleaning performed by the user 36
- Cleaning the glass 36
- Maintenance and cleaning 36
- Cleaning performed by a qualified technician 37
- Cleaning the ash 37
- Cleaning the chimney 37
- Cleaning the refractory parts alutec 37
- Maintenance and cleaning 37
Похожие устройства
- MCZ Forma 75 dx Сертификат
- MCZ Forma T95 Инструкция по эксплуатации
- MCZ Forma T95 Сертификат
- MCZ Forma 75 Инструкция по эксплуатации
- MCZ Forma 75 Сертификат
- MCZ Forma T50 Инструкция по эксплуатации
- MCZ Forma T50 Сертификат
- CAS ER JR-15CB LT черные Инструкция по эксплуатации
- CAS ER JR-15CB черные Инструкция по эксплуатации
- MCZ HydroTherm 70 dx Инструкция по эксплуатации
- MCZ HydroTherm 70 dx Сертификат
- CAS ER JR-30CB LT черные Инструкция по эксплуатации
- MCZ HydroTherm E80 Инструкция по эксплуатации
- MCZ HydroTherm E80 Сертификат
- MCZ HydroTherm 70V Инструкция по эксплуатации
- MCZ HydroTherm 70V Сертификат
- CAS ER JR-15CBU черные Инструкция по эксплуатации
- MCZ HydroTherm 80 Инструкция по эксплуатации
- MCZ HydroTherm 80 Сертификат
- CAS ER JR-30CB черные Инструкция по эксплуатации