Cleaning
Cleaning the Air Filters
Always remove the mains plug before cleaning the device.
The air fi lters should be cleaned regularly by rinsing out under
running water. Pull out the air fi lters as shown in Fig. 7.
Fig. 7
Allow the fi lters to dry before you reinstall them.
Clean the air slits on the sides regularly with a vacuum
cleaner.
Reinstall the lters, ensuring that they are inserted correctly
into the slide mounting.
CAUTION:
The protective lter must always be inserted during
operation.
The device and housing should only be cleaned with a
slightly damp cloth.
Do not use any strong detergents or solvents for cleaning.
Troubleshooting
You should not try
ner
yourself. Improper repairs mean that the guarantee is
to repair or dismantle the air-conditio
no
longervalid and place the user and other property in danger.
Problem Cause Solution
The device does
not work
or does not provide
suf cient cooling
No power supply Check the mains
connection
Timer function is
activated
Deactivate the
timer function
Windows or doors
are open, there are
many people or a
source of heat in
the room
Close the doors
and windows
Dirty fi lters Clean the fi lters
Air infl ow or outfl ow
blocked
Remove the
blockage
Room temperature
is lower than the
set value
Change the tempe-
rature selection
The device is too
loud
It is not standing
upright
Place it on a fl at,
solid surface
Control lamp „
(K) lights up
Condensation
container is full
Empty the contai-
ner (see section
on „Emptying the
Water Container“)
Noise Emissions
The noise emission value in the workplace is less than 70 dB(A).
Technical Data
Model:............................................................................... CL 3134
Power supply:............................................................230 V, 50 Hz
Power consumption:............................................................800 W
Protection class:........................................................................... Ι
Energy effi ciency class: .............................................................. A
Protection class:..................................................................... IP20
Cooling capacity:...............................................................2050 W
Refrigerant: ............................................................. R410A (420g)
Air circulation:......................................................... up to 440 m³/h
Net weight: ........................................................................28,6 kg
This device has been tested according to all relevant current
CE guidelines, such as electromagnetic compatibility and low
voltage directives, and has been constructed in accordance with
the latest safety regulations.
Subject to technical changes without prior notice!
Guarantee
The device supplied by our Company is covered by a 24 month
guarantee starting on the date of purchase (receipt).
During the life of the guarantee any fault of the device or its
accessories ascribable to material or manufacturing defects will
be eliminated free of charge by repairing or, at our discretion, by
replacing it. The guarantee services do not entail an extension
of the life of the guarantee nor do they give rise to any right to a
new guarantee!
Proof of the guarantee is provided by the proof of purchase.
Without proof of purchase no free replacement or repair will be
carried out.
If you wish to make a claim under the guarantee please return
the entire machine in the original packaging to your dealer
together with the receipt.
Defects to consumables or parts subject to wearing as well as
cleaning, maintenance or the replacement of said parts are not
covered by the guarantee and hence are to be paid!
The guarantee lapses in case of unauthorized tampering.
05-CL 3134 20 14.12.2007, 14:17:39 Uhr
The narrow fi lter is inserted on the left-hand side. Push the wide
air lter on the right-hand side
into the front guide rail.
CAUTION:
Do not use the rear guide rail. This is where the tempera-
ture sensor is located, which could be damaged.

Содержание

Скачать
Случайные обсуждения