Hotpoint-Ariston C 35S P6 R/HA [15/76] Installation

Hotpoint-Ariston C 35S P6 R/HA [15/76] Installation
GB
15
Before operating your new appliance please read
this instruction booklet carefully. It contains important
information concerning the safe installation and
operation of the appliance.
Please keep these operating instructions for future
reference. Make sure that the instructions are kept
with the appliance if it is sold, given away or moved.
The appliance must be installed by a qualified
professional according to the instructions provided.
Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected
from the electricity supply.
Room ventilation
The appliance may only be installed in permanently-
ventilated rooms, according to current national
legislation. The room in which the appliance is
installed must be ventilated adequately so as to
provide as much air as is needed by the normal gas
combustion process (the flow of air must not be lower
than 2 m
3
/h per kW of installed power).
The air inlets, protected by grilles, should have a duct
with an inner cross section of at least 100 cm
2
and
should be positioned so that they are not liable to
even partial obstruction (see figure A).
These inlets should be enlarged by 100% - with a
minimum of 200 cm
2
- whenever the surface of the hob
is not equipped with a flame failure safety device.
When the flow of air is provided in an indirect manner
from adjacent rooms (see figure B), provided that
these are not communal parts of a building, areas with
increased fire hazards or bedrooms, the inlets should
be fitted with a ventilation duct leading outside as
described above.
After prolonged use of the appliance, it is advisable to
open a window or increase the speed of any fans used.
Disposing of combustion fumes
Disposing of combustion fumes should be guaranteed
using a hood connected to a safe and efficient natural
suction chimney, or using an electric fan that begins
to operate automatically every time the appliance is
switched on (see figure).
The liquefied petroleum gases are heavier than air
and collect by the floor, therefore all rooms containing
LPG cylinders must have openings leading outside so
that any leaked gas can escape easily.
LPG cylinders, therefore, whether partially or
completely full, must not be installed or stored in
rooms or storage areas that are below ground level
(cellars, etc.). Only the cylinder being used should be
stored in the room; this should also be kept well away
from sources of heat (ovens, chimneys, stoves) that
may cause the temperature of the cylinder to rise
above 50°C.
Positioning and levelling
It is possible to install the appliance alongside
cupboards whose height does not exceed that of the
hob surface.
Make sure that the wall in contact with the beck of
the appliance is made from a non-flammable, heat-
resistant material (T 90°C).
To install the appliance correctly:
Place it in the kitchen, dining room or the bed-sit
(not in the bathroom).
If the top of the hob is higher than the cupboards,
the appliance must be installed at least 200 mm
away from them.
Installation
Adjacent room Room requiring
ventilation
A
Ventilation opening for
comburent air
Increase in the gap
between the door and
the flooring
B
A
Fumes channelled
straight outside
Fumes channelled through
a chimney or a branched
flue system (reserved for
cooking appliances)

Содержание

Installation H Hotpoint ARISTON Before operating your new appliance please read this instruction booklet carefully It contains important information concerning the safe installation and operation of the appliance Please keep these operating instructions for future reference Make sure that the instructions are kept with the appliance if it is sold given away or moved Disposing of combustion fumes GB Disposing of combustion fumes should be guaranteed using a hood connected to a safe and efficient natural suction chimney or using an electric fan that begins to operate automatically every time the appliance is switched on see figure The appliance must be installed by a qualified professional according to the instructions provided Any necessary adjustment or maintenance must be performed after the cooker has been disconnected from the electricity supply Room ventilation The appliance may only be installed in permanentlyventilated rooms according to current national legislation The room in which the appliance is installed must be ventilated adequately so as to provide as much air as is needed by the normal gas combustion process the flow of air must not be lower than 2 m3 h per kW of installed power The air inlets protected by grilles should have a duct with an inner cross section of at least 100 cm2 and should be positioned so that they are not liable to even partial obstruction see figure A These inlets should be enlarged by 100 with a minimum of 200 cm2 whenever the surface of the hob is not equipped with a flame failure safety device When the flow of air is provided in an indirect manner from adjacent rooms see figure B provided that these are not communal parts of a building areas with increased fire hazards or bedrooms the inlets should be fitted with a ventilation duct leading outside as described above Adjacent room Room requiring Fumes channelled straight outside Fumes channelled through a chimney or a branched flue system reserved for cooking appliances The liquefied petroleum gases are heavier than air and collect by the floor therefore all rooms containing LPG cylinders must have openings leading outside so that any leaked gas can escape easily LPG cylinders therefore whether partially or completely full must not be installed or stored in rooms or storage areas that are below ground level cellars etc Only the cylinder being used should be stored in the room this should also be kept well away from sources of heat ovens chimneys stoves that may cause the temperature of the cylinder to rise above 50 C Positioning and levelling It is possible to install the appliance alongside cupboards whose height does not exceed that of the hob surface Make sure that the wall in contact with the beck of the appliance is made from a non flammable heatresistant material T 90 C the flooring To install the appliance correctly Place it in the kitchen dining room or the bed sit not in the bathroom If the top of the hob is higher than the cupboards the appliance must be installed at least 200 mm away from them After prolonged use of the appliance it is advisable to open a window or increase the speed of any fans used 15