Grohe 36327000 Eurosmart Cosmopolitan E [9/92] Disposal note

Grohe 36327000 Eurosmart Cosmopolitan E [9/92] Disposal note
6
V. Mixer spindle, see fold-out pages II and III
1. Disconnect fitting from connections.
2. Remove fitting from wash basin.
Disassembly is as described in section "Setting temperature
limiter", see Fig. [8] or [10].
3. Pull out mixer spindle and replace, see Fig. [18].
Assemble in reverse order.
Replacement parts
see fold-out page I (* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Disposal note
Dispose of batteries in accordance with national
regulations.
Programme table
The infrared electronics provide seven preset programmes for selection.
Programme 1234567
Temporary shutoff*
1
Active Active Active Active Active Inactive Inactive
Automatic flushing*
2
Inactive Active Active Active Active Inactive Active
Flush interval - 72 h 24 h 72 h 72 h - 72 h
Flush duration - 5 min 5 min 10 min 1 min - 5 min
Usage-dependent - x x x - x
Usage-independent - x -
Duration of thermal disinfection 3.5 min 3.5 min 11 min 3.5 min 3.5 min 3.5 min 3.5 min
*
1
Cleaning mode can be activated when temporary shutoff is activated. In cleaning mode, water flow is not started for
3 minutes even if an object is detected.
*
2
Automatic flushing serves to ensure water hygiene in the event of long-term non-utilisation of the fitting. Flushing is initiated
for a duration of 5 minutes after 24 hours (usage-independent) or for a duration of 1 or 5 or 10 minutes after 72 hours
(usage-dependent) after the fitting was last used.
Safety note:
Ensure free draining in the case of activated automatic flushing.
Fault / Cause / Remedy
Fault Cause Remedy
Water not flowing Water supply interrupted
Filter in solenoid valve blocked
Solenoid valve defective
Plug-in connector without contact
No voltage
- Battery discharged
- Power supply unit defective
Hands not in detection zone
Cleaning mode activated
- Open shut-off valves
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
- Hold hands directly under the spout
- Deactivate cleaning mode or wait 3 minutes
Water flowing
continuously
Solenoid valve defective
Thermal disinfection activated
- Replace solenoid valve
- Wait 3.5 or 11 minutes
Undesired water
flow
Sensor system detection zone set too high
for local conditions
Automatic flushing activated
- Reduce range using remote control (special
accessory, prod. no.: 36 206)
- Wait 1 - 10 minutes
Flow rate too low Mousseur dirty
Filter in solenoid valve dirty
Filters in connection hose dirty
Water supply restricted
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Check supply lines, open shut-off valves
Mixing device
incorrect
See “Flow rate too low”
Limescale on mixer spindle - Clean or replace mixer spindle