Technical Data
Note :
(1) Nominal conditions : Air : 27 °C/19 °C wet bulb (nominal HS airflow) - Chilled water : 7 °C/12 °C.
(2) Nominal conditions : Air : 20 °C (nominal HS airflow) - Hot water : 50 °C (nominal waterflow in chilled water mode).
(3) Pressure loss by corresponding nominal flow.
(4) At nominal airflow, at 20 °C, under 230 V (see page 6).
These characteristics are for information only and are subject to change without advance.
MODELS
30
2 pipes
45
2 pipes
45
4 pipes
Nominal cooling capacity (1) - Nominal supply voltage 230V/50Hz W 6440 10190 10100
Nominal heating capacity (2) - Nominal supply voltage 230V/50Hz W 8050 11600 6670
AIR FLOW (AVERAGE VALUES) TREATED AIR
High speed m
3
/h 1550 1630 1725
Medium speed m
3
/h 1350 1250 1360
Low speed
m
3
/h 1100 1000 1075
Nominal water flow (average values) m
3
/h 1.208 1.753 1.89
Pressure loss on water
(3) kPa 17 23.5 34.3
Contents l 2.7 4 4
Power supply V
~230 V - 50 Hz
3N~400 V - 50 Hz
Voltage range
V
270 / 253 V
360 / 440 V
Power input ventilation
W 200 215 215
SOUND POWER LEVEL
High speed dBA 59 59 58
Medium speed dBA 53 54 53
Low speed
dBA 50 49 49
DIMENSIONS
Casing (W x D x H) mm 1171 x 571 x 287
Grille (W x D x H) mm 1225 x 625 x 40
Net weight kg 49 55 55
PACKING
Gross weight kg 51 58 58
Packed volume
m
3
0.31 0.31 0.31
ACCESSORIES
Electric heating (4) nominal capacity W 4300 5400 -
Motorized 3-way valve with by-pass
● ● ●
Condensing tray for valve
● ● ●
Содержание
- K og 30 45 1
- Casing 2
- Cassette air treatment unit 2
- Design features 2
- Documentation 2
- Electric heating 2
- Filtration 2
- Insulation 2
- Introduction 2
- Kits available 2
- Page 2 2
- Ventilation 2
- Page 3 3
- Technical data 3
- Condensate pump 4
- Electric heating 4
- Electric heating capacity 4
- Electrical data 4
- Page 4 4
- Cooling capacities 5
- Page 5 5
- Heating capacities 6
- Page 6 6
- Page 7 7
- Pressure drops 7
- Pressure drops at nominal flow pure water 7
- Pwo pressure drops of pure water pw pressure drops of brinewater pw k x pwo 7
- Tse outdoor dry temperature 7
- Twm average temperature of the mixture 7
- Characteristics 8
- Field of operation 8
- Page 8 8
- Thi indoor wet bulb tsi indoor dry bulb tse outdoor dry bulb twe entering water temperature 8
- Using chilled water 8
- Using hot water electric heating forbidden 8
- Fresh air intake 9
- Page 9 9
- Treated air discharge in an adjacent room 9
- Dimensions 10
- Page 10 10
- Pipe units 10
- Dimensions continued 11
- Page 11 11
- Pipe units 11
- Condensing tray for 3 way valve 12
- Motorized 3 way valve with by pass 12
- Page 12 12
- Way valve with by pass 12
- Always refer to the diagram supplied with the unit 13
- Electrical wiring diagrams standard wiring for 2 pipe cassettes 13
- The electrical wiring diagram can be modified without advance notice 13
- Electrical wiring diagrams standard wiring for 4 pipe cassettes 14
Похожие устройства
- Airwell K 30 OG 4T Инструкция по эксплуатации
- Airwell K 9 OG Инструкция по эксплуатации
- Airwell K 12 OG Инструкция по эксплуатации
- Airwell K 18 OG Инструкция по эксплуатации
- Airwell KCO LN 60 Инструкция по эксплуатации
- Airwell KCO LN 90 Инструкция по эксплуатации
- Airwell KCO LN 120 Инструкция по эксплуатации
- Airwell Wespak 1.39 Инструкция по эксплуатации
- Airwell Wespak 1.39 Технические характеристики
- Airwell Wespak 1.39 Инструкция по монтажу
- Airwell Wespak 2.69 Инструкция по эксплуатации
- Airwell Wespak 2.69 Технические характеристики
- Airwell Wespak 2.69 Инструкция по монтажу
- Airwell Wespak 3.99 Инструкция по эксплуатации
- Airwell Wespak 3.99 Технические характеристики
- Airwell Wespak 3.99 Инструкция по монтажу
- Airwell Wespak 4.05 Инструкция по эксплуатации
- Airwell Wespak 4.05 Технические характеристики
- Airwell Wespak 5.05 Инструкция по эксплуатации
- Airwell Wespak 5.05 Руководство по обслуживанию