Fluke 712C [32/42] Step and ramp modes
![Fluke 712C [32/42] Step and ramp modes](/views2/1437117/page32/bg20.png)
712C
Users Manual
24
Step and Ramp Modes
Select Step or Ramp Mode
The Product allows you to set Step and Ramp modes for
easier check of points within the linear range in output
mode.
To set the Step or Ramp mode:
1. Push .
2. Use and to select Step mode and Ramp mode.
The or icon shows on the Product display
accordingly.
Note
This function is only available when Source
mode is selected.
Set Step and Ramp Range
In Source mode, push , and then use and to
set the value of Step and Ramp.
Auto Storage of Settings
The Product automatically stores the latest settings,
including the temperature unit, the linear range of mA
converting to temperature, and sensor type.
Every time you turn on the Product, it automatically
applies the last settings.
Содержание
- C users manual 1
- Rtd calibrator 1
- Users manual 1
- Warranty 2
- Table of contents 3
- C users manual 4
- List of tables 5
- Table title page 5
- Figure title page 7
- List of figures 7
- How to contact fluke 9
- Introduction 9
- C users manual 10
- Safe working practices 11
- Safety information 11
- C users manual 12
- Table 2 international electrical symbols 12
- Standard equipment 13
- C users manual 14
- Figure 1 standard equipment 14
- Input and output terminals 15
- C users manual 16
- Figure 3 keys 17
- Figure 3 shows the product keys table 4 explains their use 17
- Rtd calibrator keys 17
- The product has keys for different purposes some keys have secondary functions that are available when shift already shows on the display 17
- Display 19
- Figure 4 elements of a typical display 19
- Figure 4 shows the elements of a typical display table 5 describes the elements 19
- Rtd calibrator display 19
- C users manual 20
- Auto backlight off 21
- Auto power off 21
- C users manual 22
- Contrast adjustment 22
- Magnet mounting and hanging strap 23
- Activate loop power supply 24
- C users manual 24
- Measure ma current 24
- Measure ma current and activate loop power supply 24
- Measure temperature 25
- Set temperature unit 25
- Use resistance temperature detectors rtds 25
- C users manual 26
- Figure 8 measure temperature with an rtd 27
- Rtd calibrator measure temperature 27
- C users manual 28
- Source temperature signals 28
- Simulate rtds 29
- C users manual 30
- Figure 10 connections for simulating 3 and 4 wire rtd 30
- Scale ma channel to temperature 31
- Set 0 and 100 output parameters 31
- Auto storage of settings 32
- C users manual 32
- Select step or ramp mode 32
- Set step and ramp range 32
- Step and ramp modes 32
- Replace the batteries 33
- C users manual 34
- Clean the product 34
- Maintenance 34
- Service center calibration or repair 34
- Replacement parts 35
- C users manual 36
- Figure 12 replacement parts 36
- Dc ma measurement 37
- Ohms measurement 37
- Specifications 37
- C users manual 38
- Ohms source 38
- Measure c source c 39
- Rtd calibrator specifications 39
- Rtd input and output 39
- Rtd type α range c 39
- Year 2 year source current 1 year 2 year 39
- C users manual 40
- General specifications 41
- Loop power supply 41
Похожие устройства
- Fluke 712C Краткий справочник
- Fluke 1551 EX Руководство по эксплуатации
- Fluke 1551A EX Руководство по эксплуатации
- Fluke 1552A Ex Руководство по эксплуатации
- Fluke 9142 Руководство по эксплуатации
- Fluke 9143 Руководство по эксплуатации
- Fluke 9144 Руководство по эксплуатации
- CALPEDA NCM 40-80/220 Инструкция по эксплуатации
- CALPEDA NCM 40-80/220 Технические характеристики
- CALPEDA NCM 40-85/220 Инструкция по эксплуатации
- CALPEDA NCM 40-85/220 Технические характеристики
- CALPEDA NC4 40-40/250 Инструкция по эксплуатации
- CALPEDA NC4 40-40/250 Технические характеристики
- CALPEDA NC 40-60/250 Инструкция по эксплуатации
- CALPEDA NC 40-60/250 Технические характеристики
- CALPEDA NC 40-120/250 Инструкция по эксплуатации
- CALPEDA NC 40-120/250 Технические характеристики
- CALPEDA NCM 40-60/250 Инструкция по эксплуатации
- CALPEDA NCM 40-60/250 Технические характеристики
- CALPEDA NCM 40-120/250 Инструкция по эксплуатации