Tektronix MSO46 — настройка поиска данных в FlexRay: Полное руководство [321/628]

Tektronix MSO44 [321/628] Flexray serial bus search configuration menu
Field or control Description
Data Bytes Sets the number of client data bytes for which to search (one to sixteen bytes). Use the A knob
to change the value.
Only available when Mark On = Client Data.
Byte Offset Sets the client data byte offset (Don't Care or the number of bytes). Tap the field and use the A
knob to change the value.
Only available when Mark On = Client Data.
Client Data Sets the data pattern for which to search. The number of bits shown depends on the Data
Bytes setting. Use in conjunction with the Mark When field to specify the exact search
condition.
Tap the Binary, Hex or ASCII field and use the A and B knobs to select and change the values.
Or double-tap on the field and use the virtual keypad to enter values.
Only available when Mark On = Client Data.
Mark When Sets the mark when condition.
When set to Inside Range or Outside Range, fields are displayed to set a high and low
boundary pattern for the specified search range.
Tap the Binary or Hex field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Only available when Mark On = MAC Length/Type or Client Data.
A, B knob controls Use the A knob to select (highlight) the digit(s) to change.
Use the B knob to change the value of the digit(s).
Copy Trigger Settings to
Search
Sets the search criteria to match the current oscilloscope trigger settings.
Copy Search Settings to
Trigger
Sets the current oscilloscope trigger settings to match the search criteria.
FlexRay serial bus search configuration menu
Use the FlexRay Search configuration menu to define conditions to search for and mark on an FlexRay bus waveform. You can
have multiple searches on the same bus.
NOTE. Requires option SRAUTO.
Field or control Description
Display Enables or disables displaying search marks on this search.
Stop Acquisition if Event
Found
Stops input acquisition when the search event occurs. Default is not enabled.
Source Select the FlexRay bus for which to search.
Mark On Select the type of information for which to search.
Menus and dialog boxes
4/5/6 Series MSO Help 291

Содержание

Узнайте, как настроить параметры поиска данных в FlexRay, включая управление байтами, условиями и триггерами. Оптимизируйте свои настройки для эффективного анализа.