User’s Guide for DS1000B Series
II
Safety Notices
view the following safety precautions
carefully before operating the
instrument to avoid any personal
injuries or damages to the instrument
and any products connected to it. To
avoid potential hazards use the
instrument as specified by this user’s
guide only.
The instrument should be serviced
by qualified personnel only.
To Avoid Fire or Personal Injury.
Use Proper Power Cord.
Use the power cord designed for the
instrument and authorized in your
country only.
Ground The Instrument.
The oscilloscope is grounded through
the grounding conductor of the power
cord. To avoid electric shock the
instrument grounding conductor(s)
must be grounded properly, before
making connections to the input or
output terminals of the instrument.
Connect The Probe.
The probes’ ground terminals are at the
same voltage level of the instrument
ground. Do not connect the ground
terminals to a high voltage.
Observe All Terminal Ratings.
To avoid fire or shock hazard, observe
all ratings and marks on the instrument.
Follow the user’s guide for further
ratings information before making
connections to the instrument.
Do Not Operate Without Covers.
Do not operate the instrument with
covers or panels removed.
Use Proper Fuse.
Use the fuse of the type, voltage and
current ratings as specified for the
instrument.
Avoid Circuit or Wire Exposure.
Do not touch exposed connections and
components when power is on.
Do Not Operate With Suspected
Failures.
If suspected damage occurs with the
instrument, have it inspected by
qualified service personnel before
further operations.
Provide Proper Ventilation.
Refer to the installation instructions for
proper ventilation of the instrument.
Do Not Operate in Wet Conditions
In order to avoid short circuiting to the
Содержание
- Ds1000b series digital oscilloscopes 1
- Ds1074b ds1104b ds1204b 1
- User s guide 1
- Contact us 3
- Guaranty and declaration 3
- Product certification 3
- Safety notices 4
- Safety terms and symbols 6
- General purpose oscilloscopes 7
- Document overview 9
- Contents 10
- Chapter 1 quick guide 13
- Quick guide 13
- General inspect 14
- Front panel 15
- Panels and user interface 15
- Rear panel 16
- User interface 18
- Functional check 19
- To compensate the probes 21
- To display a signal automatically 22
- To understand the vertical system 23
- To understand the horizontal system 25
- To understand the trigger system 27
- To understand the quick function 29
- Chapter 2 operating your oscilloscope 31
- Operating your oscilloscope 31
- To set up the vertical system 32
- Channel settings 34
- Math function 44
- Ref function 50
- To set up the horizontal system 58
- Delayed scan 61
- X y format 62
- To set up the trigger system 63
- Edge trigger 64
- Pulse width trigger 65
- Video trigger 66
- Pattern trigger 69
- Alternative trigger 71
- Trigger settings 74
- Trigger holdoff 76
- Trigger terms explanation 77
- To set up the sampling system 80
- To set up the display system 84
- To store and recall 87
- Internal memory 90
- External memory 91
- U disk selection 92
- Disk management 93
- To set up the utility 96
- The i o setup 98
- Language 106
- Pass fail 107
- Waveform recorder 110
- Print setting 114
- Self calibration 118
- System information 119
- Preference 120
- Date and time 121
- To measure automatically 122
- Quick measurement setup 124
- Delay phase setup 125
- Voltage measurements 126
- Time measurements 128
- To measure with cursors 131
- Manual mode 132
- Track mode 134
- Auto mode 136
- To use run control buttons 137
- Application examples 139
- Chapter 3 application examples 139
- Example 1 taking simple measurements 139
- Example 2 view a signal delay caused by a circuit 140
- Example 3 capture a single shot signal 141
- Example 4 to reduce the random noise on a signal 142
- Example 5 making cursor measurements 144
- Example 6 the application of the x y operation 146
- Example 7 triggering on a video signal 148
- Example 8 fft cursor measurement 150
- Example 9 pass fail test 151
- Chapter 4 troubleshooting 153
- Troubleshooting 153
- Chapter 5 specifications 155
- Specifications 155
- Technical specifications 156
- General specifications 161
- Appendix a ds1000b series accessories 163
- Appendixes 163
- Chapter 6 appendixes 163
- Appendix b warranty 164
- Appendix c general care and cleaning 165
Похожие устройства
- Bruno Sohnle 17-93102-952MB Инструкция по эксплуатации
- Rigol DS1204B Инструкция по эксплуатации(ENG)
- Alpine DVR-F200 Руководство по эксплуатации
- Alpine HCE-CS1100 Руководство пользователя
- Alpine HCE-C1100D Руководство пользователя
- Alpine HCE-C1100 Руководство пользователя
- Alpine KCX-C2600B Руководство пользователя
- Morgan M1103B Инструкция по эксплуатации
- Alpine KIT-R1AU Инструкция по установке
- Morgan M1105RGM Инструкция по эксплуатации
- Morgan M1107BR Инструкция по эксплуатации
- Morgan M1115SM Инструкция по эксплуатации
- Morgan M1120WN Инструкция по эксплуатации
- Morgan M1127WRGBR Инструкция по эксплуатации
- Morgan M1128SBR Инструкция по эксплуатации
- Morgan M1130BMBR Инструкция по эксплуатации
- Morgan M1131W Инструкция по эксплуатации
- Morgan M1132GMBR Инструкция по эксплуатации
- Morgan M1135BMBR Инструкция по эксплуатации
- Morgan M1136WRGBR Инструкция по эксплуатации