Earth Ground Tester
Symbols
3
• Do not open the battery compartment when leads are
connected.
• While a measurement is in progress, do not touch the
earth electrode, auxiliary electrode or probe.
Symbols
The following symbols are found on the Tester or in this manual.
X
Hazardous voltage. Voltage >30 V dc or ac peak might
be present.
W
Risk of danger. Important information. See Users
Manual.
T Double insulation
Battery
P Conforms to relevant European Union directives
~
Do not dispose of this product as unsorted municipal
waste. Contact Fluke or a qualified recycler for disposal.
CAT II
The enclosure is designed for 600V CATII pollution
degree 2 to cover unintended connection to hazardous
fault voltages at the earthing system.
CAT II equipment is designed to protect against
transients from energy-consuming equipment supplied
from the fixed installation, such as TVs, PCs, portable
tools, and other household appliances.
Содержание
42- Earth ground tester
- Limited warranty and limitation of liability
- Title page
- Table of contents
- Table title page
- List of tables
- List of figures
- Figure title page
- Unpacking
- Packing
- Introduction
- Earth ground tester
- Xw warning
- Safety regulations
- Symbols
- Cat ii
- Accessories
- Features
- Software
- Lcd display
- To disable auto shut off simultaneously press and hold start and display while setting the rotary switch to any on position 3 pole 2 pole or limit to reset auto shut off or to reset the tester turn off the tester and then turn it on again
- The tester has an auto shut off feature that turns the device off after 10 minutes of inactivity the tester beeps to alert you that it is about to turn off
- The tester automatically checks for interference voltage noise fault voltage above 20 v interference above 20 v greatly diminishes the accuracy of measurements if the tester detects interference voltage above 20 v the measurement automatically stops the w icon flashes the u icon displays and the value of the stray voltage displays
- Interference detection
- Auto shut off
- Resistance limit mode
- Battery installation
- Operating instructions
- Xw warning
- Pole measurement
- Users manual
- Figure 4 three pole measurement setup
- Ac resistance measurement
- Troubleshooting
- To troubleshoot your tester follow the steps in table 4
- Specifications
- Measuring time 8 seconds average from when start is pressed
- Limit input tester retains set value even if instrument is turned off assuming battery power supply is sufficient
- If tester detects stray interference voltage 20 v w is displayed and the measurement is not started
- Earth ground tester specifications
- Storage
- Service
Похожие устройства
-
Fluke 568Инструкция к устройству -
Fluke 566Руководство пользователя -
Fluke 561Инструкция по применению -
Fluke 724Руководство по калибровке -
Fluke 724Паспорт безопасности -
Fluke 705Информация о калибровке -
Fluke 705Loop Calibrators Data Sheet -
Fluke 705Паспорт безопасности -
Fluke 705Приложение к паспорту безопасности -
Fluke 705Приложение к Инструкции -
Fluke 705Дополнение к информации о калибровке -
Fluke 707 exПриложение к Руководству по эксплуатации
Узнайте о безопасных практиках использования тестера заземления, включая символы, риски и рекомендации по утилизации. Обеспечьте безопасность при измерениях.