Dometic TEC 40D [14/340] Operating the generator

Dometic TEC 40D [14/340] Operating the generator
EN
Operating the generator TEC40D
14
Displays
8 Operating the generator
A
I
8.1 Basic notes on operation
!
No. in
fig. 3,
page 4
Description
6 AC supply Actual voltage output
7 Constant output Current capacity of connected consumer
8 Operating hours Time the generator is in operation
9 DC voltage Battery voltage
10 Messages Status reports of the generator (see chapter
“Display messages” on page 16)
NOTICE!
Do not run the generator over 70 % of the maximum constant output for
the first 50 operating hours (run-in phase).
NOTE
Run the generator at a maximum of approx. 75 % of the maximum con-
tinuous load after the run-in phase.
By doing this you can prolong the service life of the generator and
maximise its efficiency.
CAUTION! Beware of injury
Do not insert your fingers or objects into the air nozzles or the intake
grille.