Dometic TEC 40D [25/340] Troubleshooting

Dometic TEC 40D [25/340] Troubleshooting
EN
TEC40D Troubleshooting
25
11 Troubleshooting
Fault Cause Remedy
The control panel
does not come on
when the on/off
switch is pressed.
Starter battery is flat.
Charge the starter battery.
Power cable is disconnected or the plug
is removed.
Contact an authorised workshop.
Fuse (if present) is triggered.
The starter does
not work when the
start button is
pressed.
Starter battery is flat.
Charge the starter battery.
The main switch is at “0”.
Set the main switch to “I” or “1”.
Circuit board is damaged.
Contact an authorised workshop.
Starter is not receiving any power.
The starter turns
but the generator
does not start.
Fuel injector is dirty.
Contact an authorised workshop.
Engine is defective.
The generator
tends to go off.
Too much oil in the engine.
Drain the oil (see chapter “Chang-
ing the oil” on page 22).
Load is too high.
Reduce the consumers.
Air intake is blocked.
Check the air filter (see chapter
“Servicing the air filter” on
page 23).
Inverter is damaged.
Contact an authorised workshop.
Fault in the injection pump power supply.
Fuel injector is dirty.
The generator is
running but does
not supply any volt-
age.
Inverter is damaged.
Contact an authorised workshop.
The electrical connections are not con-
nected properly.
Check the electric connections.
The generated
voltage is unstable.
Load is too high.
Reduce the consumers.
Air intake is blocked.
Check the air filter (see chapter
“Servicing the air filter” on
page 23).
Inverter is damaged.
Contact an authorised workshop.
Fault in the injection pump power supply.
Fuel injector is dirty.
The battery
charger is not sup-
plying any voltage.
Battery charger fuse is damaged.
Replace fuse.
TEC40D-O-16s.book Seite 25 Freitag, 12. August 2016 7:10 19