Dometic TEC 40D [18/340] Checking the oil level

Dometic TEC 40D [18/340] Checking the oil level
EN
Operating the generator TEC40D
18
8.7 Checking the oil level
!
I
Always check the oil level before use. To do this, proceed as follows:
Open the generator cover.
Switch the generator to no function with the main switch (fig. 4 1, page 4).
Disconnect the positive terminal of the supply battery.
Take the dipstick (fig. 4 2, page 4) out of the filler neck (fig. 4 3, page 4).
Clean the dipstick (fig. 4 2, page 4) with a cloth.
Put the dipstick (fig. 4 2, page 4) back into the filler neck (fig. 4 3, page 4).
Take the dipstick (fig. 4 2, page 4) out of the filler neck.
Check that the oil level is between the notch (maximum filling level) and the tip of
the dipstick.
If not, top up with more oil.
Put the dipstick (fig. 4 2, page 4) back into the filler neck (fig. 4 3, page 4).
Connect the generator to the positive terminal of the supply battery.
Switch the generator to standby with the main switch (fig. 4 1, page 4).
Close the generator cover.
GEN ON
The generator is operating nor-
mally.
Normal mode
GEN OFF
The generator is in stand-by and
can be started.
CAUTION!
Hot oil can cause burns.
Only check the oil level when the generator is switched off.
NOTE
The generator must be level.
Display message
Description
Generator behaviour Measures