Dometic TEC 40D [22/340] Changing the oil

Dometic TEC 40D [22/340] Changing the oil
EN
Servicing the generator TEC40D
22
10.4 Changing the oil
!
A
You may use the following oil:
Oil with the specifications:
CCMC D4, D5, PD
API CD, CE, CF, CG
–SHPD
SAE grade oils:
–5W-30
–5W-40
–100W
100W-30 (recommended)
–10W-30
–15W-30
–30
–40
Oil with single grade oil viscosity:
Select the appropriate viscosity according to the average temperature on-site.
Change the oil as follows (fig. 6, page 5):
Allow the generator to run warm for three to five minutes so that the oil can drain
off faster and completely.
Take the dipstick (1) out of the filler neck (2).
Place a suitable receptacle (4) near the oil hose (5).
Loosen the clamp (3).
Take off the oil hose (5) and let the oil drain off into the receptacle (4).
Put the oil hose (5) onto the hose-end fitting.
Fasten the oil hose (5) with the clamp (3).
CAUTION!
Hot oil can cause burns.
NOTICE!
Only dispose of used oil at a specialist recycling station and observe the
local laws for environmental protection.
TEC40D-O-16s.book Seite 22 Freitag, 12. August 2016 7:10 19