Tascam CD-9010CF [41/56] Other settings and information display

Tascam CD-9010CF [41/56] Other settings and information display
TASCAM CD-9010CF
41
8 – Other settings and information display
Setting the digital reference level
You can set the digital headroom (number of dB below
maximum analog output reference level (full scale).
1. Press the MENU button to open the
MENU
screen.
2. Open the
SYSTEM
menu.
3. Select
DIGITAL REF LVL
.
4. Press the DATA dial to move the cursor right to select the
setting.
5. Turn the DATA dial to set the digital reference level.
Options:
20dBFS
,
18dBFS
(default value),
16dBFS
,
14dBFS
,
9dBFS
6. After completing the setting, press the HOME button to
return to the Home Screen.
NOTE
The digital reference level setting is retained even when the
power is turned OFF.
Setting the analog reference level
You can set the analog output reference level.
The analog audio output reference level settings that are
possible depend on the digital reference level setting.
1. Press the MENU button to open the
MENU
screen.
2. Open the
SYSTEM
menu.
3. Select
ANALOG REF LVL
.
4. Press the DATA dial to move the cursor right to select the
setting.
5. Turn the DATA dial to set the analog reference level. The
analog reference setting value options depend on the
DIGITAL REF LVL
setting.
DIGITAL REF LVL setting ANALOG REF LVL setting
-9dBFS
+6dBu
only
Settings other than
-9dBFS -20dBu
,
+4dBu
(default value)
6. After completing the setting, press the
HOME
button to
return to the Home Screen.
NOTE
The –20dBu setting does not effect the MONITOR OUTPUTS.
When this setting is selected, the output from the MONITOR
OUTPUTS will be +4 dBu unless the digital reference level is
set to –9 dBFS.
This analog reference level setting is retained even when the
power is turned OFF.