Siemens 6SL3210-1SE16-0UA0 — интеграция компонентов системы и модуля датчиков для энкодеров [220/318]

Превью страниц Страница 220 / 318
Siemens 6SL3210-1SE16-0UA0 [220/318] Supplementary system components and encoder system integration
Supplementary system components and encoder system integration
7.4 Sensor Module Cabinet-Mounted SMC30
Manual
220 Manual, 01/2011, 6SL3097-4AC10-0BP2
Parameter Designation Threshold Min. Max. Unit
"Zero pulse inactive time"
(before and after A=B=high)
t
Lo
640 (t
ALo-BHi
- t
Hi
)/2
4)
ns
"Zero pulse active time"
(while A=B=high and beyond)
5)
t
Hi
640 t
ALo-BHi
- 2*t
Lo
4)
ns
1) Other signal levels according to the RS 422 standard.
2) The absolute level of the individual signals varies between 0 V and VCC of the encoder system.
3) Only with order number 6SL3055-0AA00-5CA2 and firmware version 2.5 SP1 or higher can this value be configured
using software. For older firmware releases and Order Nos. less than 6SL3055-0AA00-5CA2 then the "low" threshold
applies.
4) t
ALo-BHi
is not a specified value, but is the time between the falling edge of track A and the next but one rising edge of
track B.
5) Further information on setting the "Zero pulse active time" can be found in the manual: SINAMICS S120, Function
Manual, tolerant encoder monitoring for SMC30
Table 7- 21 Encoders that can be connected
X520
(SUB-D)
X521
(terminal)
X531
(terminal)
Track
monitoring
Remote Sense
2)
HTL bipolar 24 V No/yes Yes No/yes No
HTL unipolar 24 V
1)
No/yes Yes (however, a bipolar
connection is recommended)
1)
No No
TTL bipolar 24 V Yes Yes Yes No
TTL bipolar 5 V Yes Yes Yes To X520
SSI 24 V/5 V Yes Yes No No
TTL unipolar No
1) Because the physical transmission media is more robust, the bipolar connection should always be used. The unipolar
connection should only be used if the encoder type does not output push-pull signals.
2) A controller compares the encoder system supply voltage - sensed via the Remote Sense cables - with the reference
supply voltage of the encoder system, and adjusts the supply voltage for the encoder system at the output of the drive
module until the required supply voltage is obtained directly at the encoder system (only for 5 V encoder system power
supply).
Table 7- 22 Maximum encoder cable length
Encoder type Maximum encoder cable length in m
TTL
1)
100
HTL unipolar
2)
100
HTL bipolar 300
SSI 100
1) For TTL encoders at X520 → Remote Sense → 100 m
2) Because the physical transmission properties are more robust, the bipolar connection should
always be used. The unipolar connection should only be used if the encoder type does not output
push-pull signals.