Siemens 6SL3210-1SE14-1UA0 [31/318] Line contactor this is required for galvanic isolation
Manual
Manual, 01/2011, 6SL3097-4AC10-0BP2
31
Mains connection and line-side power components
2
2.1 Introduction
The following line-side components should be used to connect a SINAMICS Blocksize drive
line-up to the supply network:
Line disconnector
Overcurrent protection device (line fuse or circuit breaker)
Line contactor (this is required for galvanic isolation)
Line filter (optional for Power Module PM340, frame size FSA)
Line reactor (optional).
The possible supply voltages for the drive line-up are
1-ph. 200 V to 1-ph. 240 V AC ± 10%
3-ph. 380 V to 3-ph. 480 V AC ± 10%
The following line reactor variants are available:
3 versions for frame sizes FSA - FSC (chassis)
5 versions for frame sizes FSD - FSF (3 chassis and 2 standalone)
The following line filter variants are available:
Integrated
External
Base
Standalone
7KUHHSKDVH
0RWRU
2SWLRQDO
OLQHUHDFWRU
2SWLRQDO
OLQHILOWHU
&RQWDFWRU
)XVH
3RZHU0RGXOH
%ORFNVL]H
:
9
8
/
/
3(
/
3(
3(
/
/
/
Figure 2-1 Example of a line connection for Power Modules blocksize with no integrated line filter