Siemens 6SL3210-1SE16-0UA0 — designing Cabinets for Electromagnetic Compatibility in Systems [254/318]

Превью страниц Страница 254 / 318
Siemens 6SL3210-1SE31-5UA0 [254/318] Notes on electromagnetic compatibility emc
Cabinet design and EMC for components, Blocksize format
9.3 Notes on electromagnetic compatibility (EMC)
Manual
254 Manual, 01/2011, 6SL3097-4AC10-0BP2
9.3 Notes on electromagnetic compatibility (EMC)
Requirements to implement EMC are listed in EN 61000-6-2, EN 61000-6-4, EN 61800-3,
EN 60204-1 and in the EMC Design Directives - Order No. 6FC5297-0AD30-0*P2
(*A: German, *B: English). Conformance with the EMC Directive of the EC can be secured
by following the measures described in the EMC Design Directives.
When mounting components in cabinets, in order to fulfill the EMC directive, the following
conditions must be additionally observed:
Connected to TN line supply systems with grounded neutral point
SINAMICS line filter (optional for frame size FSA)
Observance of information about cable shielding and equipotential bonding
Only the recommended Siemens power and signal cables are used
Only cables from Siemens may be used for DRIVE-CLiQ connections.
For MOTION-CONNECT cables, refer to catalog PM21
CAUTION
If couplings or cabinet glands are needed for the DRIVE-CLiQ connections, only the
DRIVE-CLiQ coupling and DRIVE-CLiQ cabinet gland, described in the Chapter
Accessories, may be used.
DANGER
If the shielding procedures described and the specified cable lengths are not observed, the
machine may not operate properly.