86 Chapter 6 Parameter Description
When the pulse signal counting of the terminal input complies with the preset condition, the terminal Yi
will output corresponding instructions. The setting procedures are as follows:
1. Set Xi (i=1 to 7) terminal to “28: Counter trigger input”, and meanwhile set P5.12 and P5.13 .suck as
P5.12=4 and P5.13=8 .
2. The terminal Yi is set to “10: Preset counting value action”, and the action sequence is shown as Out1
in Fig.6-18. Effective level will be output when the counting value is between the values of P5.12 and
P5.13.
The terminal Yi is set to “11: Reaching counting value action”, and the action sequence is shown as Out2
in Fig.6-18. Effective level will be output and kept till the counting value changes when the counting value
reaches the value of P5.13.
Note:
P5.12 cannot be set to a value of higher than P5.13, and the counter pulse signal frequency
range is 0Hz to 200Hz. The voltage range is 24V±20%.
Set Xi (ii=1 to 7) terminal to “29: Counter trigger reset”, and reset the counting value when the
terminal Xi is enabled.
Xi Counting Xi Counting
Fig.6-18 Schematic diagram for the preset and reaching counting value reference
6.7 Analog Reference Parameter (Group P6)
This function is used to perform calibration on the signals that are input via different input channels with
different analog input curves.
P5.12 Preset counting value reference 0 ~ 9999(0)
P5.13 Reached counting value reference 0 ~ 9999(0)
P6.00 AI1 to AI3 and DI analog value input curve selection
0~ 44444444