Tecorp HC2V9P43P7 [25/182] P 4110 and above products are equipped with external dc reactor as standard

Tecorp HC2V8G4090 [25/182] P 4110 and above products are equipped with external dc reactor as standard
High Performance Vector Control /Torque Control Inverter User Manual
Chapter 1 Introduction to V8/V9 Series Inverter 3
P-4□□□ Three-phase 400V Variable torque/light-duty application
Power (kW) 41P5
42P2
43P7
45P5
47P5
4011
4015
4018
4022
4030
4037
4045
4055
4075
4090
Motor
power (kW)
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
Voltage (V) Three-phase 0 to rated input voltage
Rated current (A)
3.3
5.0
7.5
11
17
22
30
36
45
56
72
91
110
142
176
Output
Overload capacity
115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)
Rated
voltage/frequency
Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage
fluctuation range
323V ~ 528V; Voltage unbalancedness: 3%; allowable frequency fluctuation: ±5%
Input
Rated current (A)
5.6
8.1
13.5
19.5
26
39
50.3
60
69.3
86
104
124
150
190
235
Braking unit Built-in as standard Built-in as option
Protection class IP20
Cooling mode Self-cooling
Forced air convection cooling
Power (kW)
4110
4132
4160
4200
4220
4280
4315
4355
4400
4450
Motor
power (kW)
110
132
160
200
220
280
315
355
400
450
Voltage (V) Three-phase 0 to rated input voltage
Rated current (A)
210
253
304
380
426
520
585
650
740
840
Output
Overload capacity
115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)
Rated
voltage/frequency
Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage
range
323V ~ 528V; Voltage unbalancedness 3%; allowable frequency fluctuation: ±5%
Input
Rated current (A)
196*
232*
282*
352*
385*
491*
552*
624*
704*
792*
Braking unit External braking unit needed
Protection class IP20
Cooling mode Forced air convection cooling
* P-4110 and above products are equipped with external DC reactor as standard.
G-4□□□ Three-phase 200V Constant torque/heavy-duty application
Power (kW) 40P4 40P7 41P5 42P2
Motor
power (kW)
0.4 0.75 1.5 2.2
Voltage (V) Three-phase 0 to rated input voltage
Rated current (A) 2.6 4.5 7.5 10
Output
Overload capacity
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes
(inverse time lag feature)
Rated
voltage/frequency
Three-phase or single-phase 200V~240V; 50Hz/60Hz
Allowable voltage
range
180V ~ 260V; Voltage unbalancedness 3%; allowable frequency fluctuation: ±5%
Input
Rated current (A) 5.5 9.2 14.5 23
Braking unit Built-in as standard
Protection class IP20
Cooling mode Self-cooling Forced air convection cooling

Содержание

Скачать