18.4.2 Configure cfm domain
Configure it in global configuration mode:
Configure cfm domain
cfm domain domain-name level level-id
Parameter :
domain-name:CFM domain name
level-id: the integrity from 0-7
Remove cfm domain
no cfm domain level level-id
It is defaulted not to configure cfm domain.
For example:
! Configure cfm domain customer level 7
QTECH(config)#cfm domain customer level 7
18.4.3 Configure cfm mep level
Configure it in interface configuration mode:
Configure cfm mep level
cfm mep level level-id direction {up | down } mpid mep-id vlan vlan-id
Parameter :
level-id the integrity from 0-7
up: direction of MEP
down: direction of MEP
mep-id: MEP id
vlan-id: VLAN of MEP
Delete cfm mep level
no cfm mep level level-id vlan vlan-id
It is defaulted not to configure cfm mep level.
For example:
! Configure cfm mep level 7 direction up mpid 7110 vlan 110
QTECH(config-if-ethernet-0/1)#cfm mep level 7 direction up mpid 7110 vlan 110