Qtech QSW-2900-24T-AC [206/209] Enable disable vlan sending cfm cc enable level

18-204
no cfm cc interval
The default cfm cc interval is 10s
For example:
! Configure cfm cc interval to be 1s
QTECH(config)#cfm cc interval 1
18.4.7 Enable/disable VLAN sending cfm cc enable level
Configure it in global configuration mode:
Enable VLAN sending cfm cc enable level
cfm cc enable level level-list vlan vlan-list
Parameter :
level-list: level list needed enabling
vlan-list: VLAN list needed enabling
Disable VLAN sending cfm cc enable level
no cfm cc enable level level-list vlan vlan-list
It is defaulted to enable VLAN sending cfm cc enable level.
For example:
! Configure cfm cc enable level 0-7 vlan 1-10
QTECH(config)#cfm cc enable level 0-7 vlan 1-10
18.4.8 cfm ping
cfm ping command is used to check network connection and the arrival of destination mac address. Configure
it in global configuration mode:
cfm ping [-c count] [-s packetsize] [-t timeout] mac level level-id vlan vlan-id
Parameter:
-c count:the number of sending packet.
-s packetsize:the length of sending packet which is in the unitof bit.
-t timeout:the response timeout after sending packet which is in the unit of seconds.
mac:the destination mac address needed ping.
level-id: the integrity from 0-7
vlan-id: the VLAN needed ping.
For example:
! cfm ping 00:1f:ce:10:14:f1 level 7 vlan 110
QTECH#cfm ping 00:1f:ce:10:14:f1 level 7 vlan 110
PING 001f.ce10.14f1:
reply from 001f:ce10:14f1
reply from 001f:ce10:14f1
reply from 001f:ce10:14f1