Harvia The Wall Combi SW45SA [27/52] Instructions for installation

Harvia The Wall Combi SW45S [27/52] Instructions for installation
EN DE
27
3. INSTRUCTIONS FOR INSTALLATION
3. MONTAGEANLEITUNG
Table 2. Installation details of a Combi heater
Tabelle 2. Montageinformationen zum Combi Saunaofen
3.1. Before Installation
Before installing the heater, study the instructions
for installation. Check the following points:
Is the output and type of the heater suitable for
the sauna room? The cubic volumes given in
table 2 should be followed.
Is the supply voltage suitable for the heater?
The location of the heater fulfils the minimum
requirements concerning safety distances given
in fig. 6 and table 2.
It is absolutely necessary to ensure that the installation
is carried out according to these values. Neglecting
them can cause a risk of fire.
Only one electrical heater may be installed in
the sauna room.
The heater should be installed so that the
warning texts can also be read without
difficulty after the installation.
The heaters must not be mounted in a recess.
3.2. Safety Railing
If a safety railing is built around the heater, the
minimum distances given in fig. 6 and table 2 must
be observed.
3.1. Vor der Montage
Lesen Sie die Montageanleitung, bevor Sie den Sau-
naofen installieren. Überprüfen Sie die folgenden
Punkte:
Ist der zu montierende Saunaofen in Leistung
und Typ passend für die Saunakabine? Die
Rauminhaltswerte in Tabelle 2 dürfen weder
übernoch unterschritten werden.
Ist die Netzspannung für den Saunaofen geeig-
net?
Der Montageort des Ofens er füllt die in Abb. 6
und Tabelle 2 angegebenen Sicherheitsmindest-
abstän de.
Diese Abstände müssen unbedingt eingehalten
werden, da ein Abweichen Brandgefahr verursacht.
In einer Sauna darf nur ein Saunaofen installiert
werden.
Der Saunaofen muß so installiert werden, daß
die Warnanweisungen nach der Montage leicht
lesbar sind.
Die Saunaöfen dürfen nicht in Wandnischen
montiert werden
3.2. Schutzgeländer
Falls um den Saunaofen ein Schutzgeländer gebaut
wird, muß dies unter Berücksichtigung der in Abb.
6 und in Tabelle 2 ange gebenen Mindestsicherheits-
abstände geschehen.
Heater
Ofen
Output
Leistung
Vaporizer
Verdampfer
Dimensions
Abmessungen
Stones
Steine
Sauna room
Saunakabine
Output
Leistung
Max. vaporisation
efficiency
Verdampfungs-
leistung
Lev./syv./kork.
Bredd/djup/höjd
Weight
Vikt
Volume
Rauminhalt
Height
Höhe
kW kW kg/h mm kg max. kg
2.3.!
min. m³ max. m³ min. mm
SW45S/SW45SA 4,5 2,0 2,5 380/355/710 16,0 20 5 10 1900
SW70S/SW70SA 7,0 2,0 2,5 380/355/710 16,8 20 8 14 1900
SW90S/SW90SA 9,0 2,0 2,5 380/355/710 16,8 20 9 18 1900
Figure 6. Safety distances (all dimensions in millimeters)
Abbildung 6. Sicherheitsmindestabstände (alle Abmessungen in Millimetern)
min. mm
A B C D E
SW45S/SW45SA 20 20 35 80 1200
SW70S/SW70SA 20 20 70 80 1200
SW90S/SW90SA 20 20 80 80 1200

Содержание

Похожие устройства

EN DE 3 INSTRUCTIONS FOR INSTALLATION 3 MONTAGEANLEITUNG 3 1 Before Installation 3 1 Vor der Montage Before installing the heater study the instructions for installation Check the following points Is the output and type of the heater suitable for the sauna room The cubic volumes given in Lesen Sie die Montageanleitung bevor Sie den Sau naofen installieren Überprüfen Sie die folgenden Punkte Ist der zu montierende Saunaofen in Leistung und Typ passend für die Saunakabine Die table 2 should be followed Rauminhaltswerte in Tabelle 2 dürfen weder übernoch unterschritten werden Is the supply voltage suitable for the heater The location of the heater fulfils the minimum requirements concerning safety distances given in fig 6 and table 2 Ist die Netzspannung für den Saunaofen geeig net Der Montageort des Ofens er füllt die in Abb 6 und Tabelle 2 angegebenen Sicherheitsmindest abstände It is absolutely necessary to ensure that the installation is carried out according to these values Neglecting them can cause a risk of fire Only one electrical heater may be installed in the sauna room The heater should be installed so that the warning texts can also be read without difficulty after the installation The heaters must not be mounted in a recess Diese Abstände müssen unbedingt eingehalten werden da ein Abweichen Brandgefahr verursacht In einer Sauna darf nur ein Saunaofen installiert werden Der Saunaofen muß so installiert werden daß die Warnanweisungen nach der Montage leicht lesbar sind Die Saunaöfen dürfen nicht in Wandnischen montiert werden 3 2 Safety Railing 3 2 Schutzgeländer If a safety railing is built around the heater the minimum distances given in fig 6 and table 2 must be observed Falls um den Saunaofen ein Schutzgeländer gebaut wird muß dies unter Berücksichtigung der in Abb 6 und in Tabelle 2 angegebenen Mindestsicherheits abstände geschehen Heater Ofen Output Leistung Vaporizer Verdampfer Max vaporisation Output efficiency Leistung Verdampfungs Dmensions Abmessungen Lev syv kork Bredd djup höjd Stones Steine Weight Vikt mm 380 355 710 380 355 710 380 355 710 kg 16 0 16 8 16 8 Sauna room Saunakabine Volume Rauminhalt Height Höhe 2 3 min m3 5 8 9 min mm 1900 1900 1900 leistung SW45S SW45SA SW70S SW70SA SW90S SW90SA kW 4 5 7 0 9 0 kW 2 0 2 0 2 0 kg h 2 5 2 5 2 5 max kg 20 20 20 max m3 10 14 18 Table 2 Installation details of a Combi heater Tabelle 2 Montageinformationen zum Combi Saunaofen SW45S SW45SA SW70S SW70SA SW90S SW90SA min mm A B C D E 20 20 20 35 70 80 80 80 80 1200 1200 1200 20 20 20 Figure 6 Safety dis tan ces all dimensions in millimeters Abbildung 6 Sicherheitsmindestabstände alle Abmessungen in Millimetern 27