SPECK Pumpen IN-VB 6-30 F [65/100] Transport and intermediate storage

SPECK Pumpen IN-VB 60-90-2 F [65/100] Transport and intermediate storage
Transport and intermediate storage
11|2018 EN 15
4 Transport and intermediate storage
4.1 Transport
Check the delivery conditions.
Check the packaging for transport damage.
Determine damages and contact the manufacturer and the insurance company.
NOTICE
Damage to the mechanical seal due to improper transportation.
When transporting the pump without the motor, protect the pump shaft from shifting using a
transport lock.
4.2 Lifting the pump
DANGER
Goods being transported can fall and result in death or crushing of limbs!
The lifting hooks on the motor are designed for the weight of the motor. The lifting hooks can break if
the complete pump unit is attached.
Attach the hoisting equipment to both the motor and pump sides if hooks are provided.
Use only hoisting and load-bearing equipment which is suitable, technically sound, and can bear
enough weight.
Never lift or transport the pump/unit using electrical connection cables.
Do not stand under suspended loads.
Only transport the pump/unit in the correct position.
Fig. 4
Fig. 5