Daikin FXFQ80PVE [53/90] Fxmq50pve

Daikin FXFQ80PVE [53/90] Fxmq50pve
Dimensions ED39-865
52 FXMQ-P (R-410A)
FXMQ50PVE
28
59
290
450 or more
2
×
65=130
3
×
65=195
(All around)
700
300
215
247
(From the Air outlet)
212
(467 or less)
(Service space)
6
×
150=900
View
144
169
925
26
60
80
700 or less
167
300 or less
232
300 or more
27
785
513
150
760
49
Adjustable
805
950
1000
245
277
150
150
or less
150
200
Air outlet
(From the Air inlet)
Air
outlet
Inspection hatch 450 or more
Air inlet
Floor surface
435
Ceilling
CASE 1)
Control box
View B-2
CASE 2), 3)
View B-1
Control box
20
or more
Control box
B
Fig. A
Unit base
Air
outlet
Air
inlet
Notes)1. Location of MANUFACTURE'S LABEL:
Contro box surface
2. Mount the air filter at the suction side.
Select its colorimethod (gravity
method) 50% or more.
3. Do not locate things should not be wet
under the indoor unit.
Dews may drop when humidity
reaches over 80%, or a drain gets
stuck, or air filters are not clean.
4. Space for Service Works
1) One inspection hatch (450 × 450) on the control box side
and a space of 300mm or more under the unit. (Fig. A)
2) One inspection hatch (450 × 450) on the control box side
and 2 (two) inspection hatches under the unit. (Arrow
View B-1)
3) 3 (three) inspection hatches under the unit and the
control box. (Arrow View B-2)
According to any one of below 1)~3), secure a space
for service works, such as, checking and maintenance
of control box and drain pumps, etc.
30-φ 4.7 hole
(All around)
36-φ 4.7 hole
8
631
(Suspention bolt position)
1038 (Suspention bolt position)
11
×
65=715
13
×
65=845
10
9
700 or more
(Service space)
3
1
2
6
5
12
7
11
4
(Note. 4)
2500 or more
(A case without
the ceiling)
Air inlet
(Note. 2)
16-8 × 12 oblong hole
(All around)
5
×
150=750
Ceiling
Inspection hatch
Inspection hatch 2
(SAME AS THE INDOOR
UNIT SIZE OR MORE)
Inspection hatch Ceiling
or more
300
or more
300
Control box
Control box
Inspection hatch 1
(450mm × 450mm)
Inspection hatch 1
(450mm × 450mm)
Inspection hatch 3
(SAME AS THE INDOOR
UNIT SIZE +300 OR MORE)
1300
700
or more
700
or more
or more
200
1000
or less
or more
(All around)
18-8 × 12 oblong hole
11
Power supply connection
7
Hoot
Socket (For maintenance)
Interunit wiring connection
6
Drain pipe connection
3
12
4
φ 12.7 flale connection
ITEM
Control box (Inside)
5
10
PART NAME
M4
VP25 (O. D. φ 32, I. D. φ 25)
VP25 (O. D. φ 32, I. D. φ 25)
For M10
REMARK
Liquid pipe connection
1
O. D. φ 32 (Outlet)
Gas pipe connection
2
Drain hose (Accessory)
Air discharge flange
8
φ 6.4 flale connection
Air suction flange
9
Ground terminal (Terminal in Control box)
3D060159B