ED39-865 Fan Performances
FXMQ-P (R-410A) 63
2
FXMQ63PVE
FXMQ80PVE
Notes :
1. As for this machine, setting is
possible by 14 position of ESP.
2. Fan characteristics 1 shows a fan
characteristic at the time of the
"maximum ESP" "rating ESP"
"minimum ESP" as a representative.
3. Fan characteristics 2 (for field
setting of remote controller) shows a
fan characteristic of each ESP of
field setting possible air flow "HH".
4. Please choose ESP setting by using
Fan characteristics 1 and Fan
characteristics 2 by the resistance
of a connected duct.
5. The remote controller can be used
to change "HH" "H" and "L".
6. ESP : external static pressure
7. The value in this figure shows ESP
in rating air flow.
22
5
250
10
25
19
50
25
15
5
20
23
150
15
16
15
0
25
17
5
21
150
100
5
1816
20
23
200
14
10
202015
0
2122 18
20
100
250
00
50
0
19
200
1713
20
25
15
10
0
10
(For local setting of remote controller)
Fan characteristics
2
1
Fan characteristics
Range of available air flow rate in [HH]
(mmH2O) (mmH2O)(mmH2O) (mmH2O)Air flow (m
3
/min) Air flow (m
3
/min)
(Pa)
(Pa)
(mmH
2O) (mmH2O) (mmH2O)(mmH2O)
(Pa)
(Pa)
External static pressure
External static pressure
HH
(min ESP)
H
(min ESP)
L
(min ESP)
H
(max ESP)
H
(rating ESP)
L
(rating ESP)
L
(max ESP)
HH
(max ESP)
HH
(rating ESP)
200Pa (Note 7)
max ESP
100Pa
rating ESP
50Pa
min ESP
180Pa
160Pa
150Pa
140Pa
130Pa
120Pa
110Pa
90Pa
80Pa
70Pa
60Pa
U
pper lim
it of E
S
P
(N
ote 6)
(m
ax E
S
P
)
Lo
w
er lim
it of E
S
P
(rating E
S
P
)
Upper limit of ESP
(rating ESP)
Upper limit of ESP
(min ESP)
Lower limit of ESP
(max ESP)
Lower limit of ESP
(min ESP)
3D060458
Notes :
1. As for this machine, setting is
possible by 14 position of ESP.
2. Fan characteristics 1 shows a fan
characteristic at the time of the
"maximum ESP" "rating ESP"
"minimum ESP" as a representative.
3. Fan characteristics 2 (for field
setting of remote controller) shows a
fan characteristic of each ESP of
field setting possible air flow "HH".
4. Please choose ESP setting by using
Fan characteristics 1 and Fan
characteristics 2 by the resistance
of a connected duct.
5. The remote controller can be used
to change "HH" "H" and "L".
6. ESP : external static pressure
7. The value in this figure shows ESP
in rating air flow.
0
5
50
0
242220 21
200
2721
250
20
22
5
23
5
26
20
27
250
50
23
25
28
25
20.5
20
200
10
20
25
0
100
24
5
15
28
15
0
100
15
26
0
150
25
19
150
15
17
10
25
0
25
10
18 28.5
10
(For local setting of remote controller)
Fan characteristics
2
1
Fan characteristics
Range of available air flow rate in [HH]
External static pressure
External static pressure
(Pa)
(mmH
2O) (mmH2O) (mmH2O)(mmH2O)
(mmH
2O) (mmH2O)(mmH2O) (mmH2O)
(Pa)
Air flow (m
3
/min) Air flow (m
3
/min)
HH
(min ESP)
H
(min ESP)
H
(max ESP)
H
(rating ESP)
L
(rating ESP)
L
(max ESP)
HH
(max ESP)
HH
(rating ESP)
200Pa (Note 7)
max ESP
100Pa
rating ESP
50Pa
min ESP
180Pa
160Pa
150Pa
140Pa
130Pa
120Pa
110Pa
90Pa
80Pa
70Pa
60Pa
L (min ESP)
U
p
p
e
r lim
it o
f E
S
P
(N
o
te
6
)
(m
a
x
E
S
P
)
Lower limit of ESP
(max ESP)
Lower limit of ESP
(rating ESP)
Upper limit of ESP
(rating ESP)
Lower limit of ESP
(min ESP)
Upper limit of ESP
(min ESP)
3D060459