8.2 “Air Flow Auto Adjustment” Characteristics
FXMQ40PVE
FXMQ50PVE
9
100
0
150
13
10
0
11
200
5
18
50
15 17
20
1612
0
15
(Pa)
14
15
10
20
5
10
Air flow (m
3
/min)
(mmH
2O)
(mmH
2O)
(mmH
2O)
Lower limit of ESP
(mmH2O) (Pa)
[ L ]
[ H ]
[ HH ]
Upper limit of ESP
(NOTE 8)
Lower limit
of ESP by
airflow auto
adjustment
Upper limit of
ESP by airflow
auto adjustment
Notes :
1. As for this machine, less than 10% of the volume of blow-off air is
automatically adjusted to the rated quantity by airflow auto adjustment at
the time of installation.
2. After duct construction completion, please perform local setting "airflow
auto adjustment" by remote controller.
3. About the local setting method of the "airflow auto adjustment", look at
the installation manual which is attached to an indoor unit.
4. External static pressure that can adjust by "airflow auto adjustment"
function is 30Pa - 160Pa (When air flow is HH).
5. It is not operated auto adjustment, operated in air flow that is different
from rated quantity in the case of use out of external static pressure
range mentioned above.
6. This figure shows a fan characteristics at the time of "HH" "H" and "L".
7. The remote controller can be used to change "HH" "H" and "L".
8. ESP : external static pressure.
External static pressure
3D060577
19 20
21
13
1814 1715
(
Pa
)
16
5
20
Air flow (m
3
/min)
(mmH
2O)
15
20
(mmH2O)
(mmH
2O)
0
5
10
0
200
Lower limit of ESP
(mmH2O)
25
100
25
External static pressure
(Pa)
0
10
15
50
150
250
[ L ]
[ H ]
[ HH ]
Upper limit of ESP
(NOTE 8)
Upper limit
of ESP by
airflow auto
adjustment
Lower limit
of ESP by
airflow auto
adjustment
Notes :
1. As for this machine, less than 10% of the volume of blow-off air is
automatically adjusted to the rated quantity by airflow auto adjustment at the
time of installation.
2. After duct construction completion, please perform local setting "airflow auto
adjustment" by remote controller.
3. About the local setting method of the "airflow auto adjustment", look at the
installation manual which is attached to an indoor unit.
4. External static pressure that can adjust by "airflow auto adjustment" function
is 50Pa - 200Pa (When air flow is HH).
5. It is not operated auto adjustment, operated in air flow that is different from
rated quantity in the case of use out of external static pressure range
mentioned above.
6. This figure shows a fan characteristics at the time of "HH" "H" and "L".
7. The remote controller can be used to change "HH" "H" and "L".
8. ESP : external static pressure.
3D060578