Daikin FXSQ63P7VEB Сервис мануал онлайн [197/370] 544693

Daikin FXSQ140PVE Сервис мануал онлайн [197/370] 544677
SiBE311209
Service Diagnosis 188
4.30 Liquid Pipe Thermistor 1 (R6T or R9T) Abnormality ............................254
4.31 Liquid Pipe Thermistor 2 (R7T) Abnormality ........................................255
4.32 Subcooling Heat Exchanger Gas Pipe Thermistor (R5T)
Abnormality ..........................................................................................256
4.33 High Pressure Sensor Abnormality ......................................................257
4.34 Low Pressure Sensor Abnormality .......................................................259
4.35 Defective Inverter PCB.........................................................................261
4.36 Inverter Radiation Fin Temperature Rise Error ....................................263
4.37 Momentary Overcurrent of Inverter Compressor..................................264
4.38 Overcurrent of Inverter Compressor.....................................................265
4.39 Inverter Compressor Starting Error ......................................................267
4.40 Transmission Error between Inverter and Control PCB .......................269
4.41 Inverter Over-Ripple Protection............................................................271
4.42 Inverter Radiation Fin Temperature Rise Abnormality .........................273
4.43 Field Setting Abnormality after Replacing Main PCB or Combination of
PCB Abnormality ..................................................................................274
4.44 Refrigerant Shortage Alert....................................................................276
4.45 Reverse Phase, Open Phase...............................................................278
4.46 Power Supply Insufficient or Instantaneous Error ................................279
4.47 Check Operation is not Executed.........................................................281
4.48 Transmission Error between Indoor Units and Outdoor Units..............282
4.49 Transmission Error between Remote Controller and Indoor Unit.........284
4.50 Transmission Error (Across Outdoor Units and Function Units) ..........285
4.51 Transmission Error between Main and Sub Remote Controllers .........292
4.52 Transmission Error between Indoor Units and Outdoor Units in the
Same System .......................................................................................293
4.53 Improper Combination of Indoor and Outdoor Units,
Indoor Units and Remote Controller.....................................................294
4.54 Centralized Address Duplication ..........................................................297
4.55 Transmission Error between Centralized Control Equipment and
Indoor Unit............................................................................................298
4.56 System is not Set yet............................................................................301
4.57 System Abnormality, Refrigerant System Address Undefined .............302
4.58 Check ...................................................................................................304

Содержание