Daikin FXSQ63P7VEB [270/370] Defective inverter pcb

Daikin FXSQ140P7VEB [270/370] Defective inverter pcb
Troubleshooting by Indication on the Remote Controller SiBE311209
261 Service Diagnosis
4.35 Defective Inverter PCB
Remote
Controller
Display
L1
Applicable
Models
Outdoor Unit: RTSQ8~16PAY1
Function Unit: BTSQ20PY1
Method of Error
Detection
Error is detected based on the current value during waveform output before starting
compressor.
Error is detected based on the value from current sensor during synchronous operation when
starting the unit.
Error Decision
Conditions
Overcurrent (OCP) flows during waveform output.
Defective current sensor during synchronous operation.
IPM failure.
Supposed
Causes
Inverter PCB (A4P)
z
IPM failure
z
Current sensor failure
z
Drive circuit failure

Содержание