Daikin FXSQ63P7VEB [215/370] Service diagnosis 206

Daikin FXZQ32MVE [215/370] Service diagnosis 206
SiBE311209 Troubleshooting by Remote Controller
Service Diagnosis 206
<Monitor mode>
To enter the monitor mode, press the
MODE (BS1) button when in “Setting
mode 1”.
<Selection of setting item>
Refer to P.172 for Monitor mode.
Refer to P.172 for Monitor mode.
Press the SET (BS2) button and set
the LED display to a setting item.
<Confirmation of error 1>
Press the RETURN (BS3) button
once to display "First digit" of error
code.
<Confirmation of error 2>
Press the SET (BS2) button once to
display "Second digit" of error code.
<Confirmation of error 3>
Press the SET (BS2) button once to
display "error location".
<Confirmation of error 4>
Press the SET (BS2) button once to
display "master or slave 1 or slave 2"
and "error location".
Detail
description
on next
page.
Press the RETURN (BS3) button and
switches to the initial status of
“Monitor mode”.
Press the MODE (BS1) button and
returns to “Setting mode 1”.
Malfunctions Malfunction
code
Description of malfunction Description of malfunction (PGF) Remote
controller
Open phase and unbalanced power
supply
Unbalanced INV power supply voltage P1
INV radiation fin temperature sensor
malfunction
INV fin thermistor malfunction P4
Faulty combination of INV and fan
driver
Faulty combination of INV PJ
Out of gas Out-of-gas alarm U0
Reversed phase Reversed phase malfunction U1
Abnormal power supply voltage Insufficient INV voltage U2
INV open phase (single phase)
Abnormal charge of capacitor of INV
main circuit
Test run not carried out yet Test run not carried out yet U3
Faulty transmission between indoor
and outdoor units
IN-OUT transmission malfunction U4
System malfunction
Faulty transmission between outdoor
units
Malfunction caused when mounting
the external control adaptor
U7
Alarm given when mounting the
external control adaptor
Malfunction caused between the
master and the slave 1
Malfunction caused between the
master and the slave 2
Multi RTSYQ models connected
Faulty address setting of slaves 1 and 2
4 or more outdoor units connected in
the same system
Erroneous address of slaves 1 and 2
Disconnection of function unit
Over-connection of function unit
Error of installation for 8, 12HP single
unit
Faulty transmission with other
systems
Other system or other unit in the same
system
U9
Faulty field setting Excess indoor units connected UA
Erroneous refrigerant used for indoor
unit
Faulty combination of outdoor units
Faulty independent installation
Faulty connection of former BS unit
Unmatched wiring/piping, no system
settings
Unmatched wiring/piping UF
Faulty system line Wrong wiring (auto address error) UH
k
: ON
l
: Blink
h
: OFF