Daikin RXYQ14P7W1B [39/80] Vrv wii heat pump heat recovery

Daikin RXYQ14P7W1B [39/80] Vrv wii heat pump heat recovery
Nominal cooling capacity kW
Nominal heating capacity kW
Capacity range HP
Power input (nominal) cooling kW
heating kW
COP cooling
heating
Max n° of indoor units to be connected
Minimum capacity index
Maximum capacity index
Power supply Y1
Dimensions height mm
width mm
depth mm
Weight kg
Colour
Sound pressure levels dBA
Sound power levels dBA
Fan type
air flow rate (nominal) m
3
/min
Refrigerant name
charge kg
control
Refrigerant Oil type
charged volume l
Compressor quantity
type
starting method
Piping Connections liquid mm
discharge gas mm
gas mm
Safety devices
VRV-WII
RWEYQ10M RWEYQ20M RWEYQ30M RWEYQ10M RWEYQ20M RWEYQ30M
26.70 53.40 80.10 26.70 53.40 80.10
31.50 63.00 94.50 31.50 63.00 94.50
10 20 30 10 20 30
6.03 12.10 18.10 6.03 12.10 18.10
6.05 12.10 18.20 6.05 12.10 18.20
4.43 4.41 4.43 4.43 4.41 4.43
5.21 5.21 5.19 5.21 5.21 5.19
16 20 32 16 20 32
125 250 375 125 250 375
325 650 975 325 650 975
3~, 50Hz, 380-415V 3~, 50Hz, 380-415V
1,000 * * 1,000 * *
780 * * 780 * *
550 * * 550 * *
150 150+150 150+150+150 150 150+150 150+150+150
Ivory white (5Y7,5/1) Ivory white (5Y7,5/1)
51.0 54.0 56.0 51.0 54.0 56.0
** ** ** ** ** **
** ** ** ** ** **
** ** ** ** ** **
R-410A R-410A
5.2 5.2+5.2 5.2+5.2+5.2 5.2 5.2+5.2 5.2+5.2+5.2
Expansion valve (electronic type) Expansion valve (electronic type)
Synthetic (ether) oil Synthetic (ether) oil
** ** ** ** ** **
1 2 3 1 2 3
Hermetically sealed scroll compressor Hermetically sealed scroll compressor
Soft start Soft start
9.52 (flare) 15.9 (flare) 19.1 (flare) 9.52 (flare) 15.9 (flare) 19.1 (flare)
22.2 (brazing) 28.6 (brazing) 34.9 (brazing) 19.1 (brazing) 22.2 (brazing) 28.6 (brazing)
- - - 22.2 (brazing) 28.6 (brazing) 34.9 (brazing)
HPS, inverter overload protector, fusible plugs HPS, inverter overload protector, fusible plugs
HEAT PUMP HEAT RECOVERY
VRV-WII HEAT PUMP / HEAT RECOVERY
p. 39
Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • inlet water temperature: 30°C • equivalent refrigerant piping: 7.5m • level difference: 0m
Nominal heating capacities are based on: indoor temperature: 20°CDB • inlet water temperature: 20°C • equivalent refrigerant piping: 7.5m • level difference: 0m
This unit should not be installed outdoors, but indoors eg. in a machine room, etc.
Indoor operating ambient temperature: 0 ~ 40°C. Heat rejection from the outdoor unit: 0,71kW/10HP
*Dimensions of 20HP and 30HP units depend on the method of stacking
**Data were not available at the time of publication
Outdoor Units
2
1602UKEPCEN07-200-artwork.indd 391602UKEPCEN07-200-artwork.indd 39 1/8/07 07:15:501/8/07 07:15:50

Содержание