Outdoor Unit SiBE041213E
11 Printed Circuit Board Connector Wiring Diagram
2.2 RXS42K2V1B
Main PCB
Caution Replace the PCB if you accidentally cut the jumpers other than J4 and J5.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
1) S20 Connector for electronic expansion valve coil
2) S40 Connector for overload protector
3) S70 Connector for fan motor
4) S80 Connector for four way valve coil
5) S90 Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
6) U, V, W Connector for compressor
7) HL1, HN1, S Connector for terminal board
8) E (E2) Connector for earth wire
9) HR1, HR2 Connector for reactor
10) LED A LED for service monitor (green)
11) FU1, FU2 Fuse (3.15 A, 250 V)
12) FU3 Fuse (30 A, 250 V)
13) J4 Jumper for facility setting
Refer to page 108 for detail.
14) J5 Jumper for improvement of defrost performance
Refer to page 110 for detail.
15) V1, V3, V4 Varistor