Daikin EHY2KOMB28AA — установка и опции для систем отопления и горячего водоснабжения [29/236]

Daikin EHY2KOMB28AA [29/236] Possible options for the outdoor unit
6 | About the units and options
Installer reference guide
29
EJHA04AAV3 + EHY2KOMB28+32AA
Daikin Altherma H Hybrid
4P531180-1B – 2020.02
6.3 Combining units and options
6.3.1 Possible combinations of outdoor unit, gas boiler and domestic hot water tank
System Remark
Outdoor unit Gas boiler DHW tank DHW Space heating
EJHA04AAV3 EHY2KOMB28
AA
EHY2KOMB32
AA
EKHWS*D* Domestic hot water by tank.
Tank heated:
By outdoor unit only, or
By gas boiler only
(a)
By outdoor unit only, or
By gas boiler only, or
By combination of outdoor
unit and gas boiler
EKHWP
Third-party
(b)
Instant domestic hot water by
gas boiler
By outdoor unit only, or
By gas boiler only, or
By combination of outdoor
unit and gas boiler
Third-party Instant domestic hot water by
gas boiler
By outdoor unit only, or
By gas boiler only (bivalent
operation)
(a)
Maximum tank setpoint is 60°C.
(b)
Third-party tank is possible, but comfort cannot be guaranteed. See the minimum requirements for third-party tanks in
"8.3.2Water circuit requirements"[462].
6.3.2 Possible options for the outdoor unit
User interface (EKRUHML*)
The user interface is required for operation, but has to be ordered separately
(mandatory option).
Following user interfaces are available:
EKRUHML1 contains the following languages: English, French, Dutch, Italian.
EKRUHML2 contains the following languages: English, German, Dutch, Italian.
For installation instructions, see "To connect the user interface"[497].
Remote outdoor sensor (EKRSCA1)
By default the sensor inside the outdoor unit will be used to measure the outdoor
temperature.
As an option the remote outdoor sensor can be installed to measure the outdoor
temperature on another location (e.g. to avoid direct sunlight) to have an
improved system behaviour.
For installation instructions, see the installation manual of the remote outdoor
sensor and the addendum book for optional equipment.
Heat pump convector (FWXV)
For providing space heating, it is possible to use heat pump convectors (FWXV).
For installation instructions, see the installation manual of the heat pump
convectors, and the addendum book for optional equipment.
LAN adapter for smartphone control + Smart Grid applications (BRP069A61)
You can install this LAN adapter to: