EJHA04AAV3 + EHY2KOMB28+32AA
Daikin Altherma H Hybrid
4P531180-1B – 2020.02
Underfloor heating or radiators – Wireless room thermostat
Setup
A
B
b
ca
A Main leaving water temperature zone
B One single room
a User interface
b Receiver for wireless external room thermostat
c Wireless external room thermostat
The outdoor unit is connected in series with the gas boiler.
The underfloor heating or radiators are directly connected to the gas boiler.
The room temperature is controlled by the wireless external room thermostat
(optional equipment EKRTR1).
Configuration
Setting Value
Unit temperature control:
#: [A.2.1.7]
Code: [C-07]
1 (Ext RT control): Unit operation
is decided by the external thermostat.
External room thermostat for the main
zone:
#: [A.2.2.4]
Code: [C-05]
1 (Thermo ON/OFF): When the used
external room thermostat or heatpump
convector can only send a thermo ON/
OFF condition.
Benefits
Wireless. The Daikin external room thermostat is available in a wireless version.
Efficiency. Although the external room thermostat only sends ON/OFF signals, it
is specifically designed for the heatpump system.