Daikin EHY2KOMB32AA — инструкция по установке и эксплуатации газового котла [26/48]
![Daikin EHY2KOMB32AA [26/48] Domestic hot water temperature](/views2/1746844/page26/bg1a.png)
7 Configuration
Installation and operation manual
26
EHY2KOMB28+32AA
Daikin Altherma H Hybrid – Gas boiler module
4P538953-1A – 2020.02
Domestic hot water comfort function
Not applicable for Switzerland
This function can be operated with the domestic hot water comfort
key ( ). The following functions are available:
▪ On: The LED lights up. The domestic hot water comfort function
is switched on. The heat exchanger will be kept on temperature to
assure instant delivery of hot water.
▪ Eco: The LED lights up. The domestic hot water comfort
function is self-learning. The appliance will learn to adapt to the
pattern of use of hot tap water. For example: the temperature of
the heat exchanger will NOT be maintained during the night or in
case of long absence.
▪ Off: Both LED's are OFF. The temperature of the heat exchanger
is NOT maintained. For example: It will take a while to deliver hot
water to the hot water taps. If there is no need for immediate hot
water delivery, the domestic hot water comfort function can be
turned off.
To reset the gas boiler
INFORMATION
Resetting is only possible when an error occurs.
Prerequisite: Flashing LED above the button and an error code
on the main display.
Prerequisite: Check the meaning of the error code (see "Error
codes of the gas boiler"[436]) and resolve the cause.
1 Press to restart the gas boiler.
Maximum space heating supply temperature
See the user reference guide for more details.
Domestic hot water temperature
See the user reference guide for more details.
Keep hot function
The reversible heat pump features a keep hot function that keeps
the heat exchanger hot continuously to prevent sweat from occurring
in the gas boiler switch box.
In case of heating only models, this function can be deactivated
through the parameter settings of the gas boiler.
INFORMATION
Do NOT deactivate the keep hot function if the gas boiler is
connected to a reversible indoor unit. It is recommended to
always deactivate the keep hot function if the gas boiler is
connected to a heating only indoor unit.
It is recommended to always deactivate the keep hot function.
Frost protection function
The boiler is equipped with an internal frost protection function that
automatically operates when necessary, even if the boiler is turned
off. If the heat exchanger temperature drops too low, the burner will
switch on until the temperature is sufficiently high again. When frost
protection is active, is displayed on the service display.
To set the parameters via the service code
The gas boiler is factory set in accordance with the default settings.
Take into account the remarks in the table below when changing the
parameters.
1 Press simultaneously on and until appears on the main
and the service display.
2 Use the and buttons to set (service code) on the main
display.
3 Press the button to set the parameter on the service display.
4 Use the and buttons to set the parameter to the desired
value on the service display.
5 When all settings are done, press until appears on the
service display.
Result: The gas boiler has now been reprogrammed.
INFORMATION
▪ Press the button to exit the menu without storing the
parameter changes.
▪ Press the button to load the default settings of the
gas boiler.
Parameters on the gas boiler
Parameter Setting Range Default
settings
Description
Service code — — To access the installer settings, enter
the service code (=15)
Installation type 0~3 0 ▪ 0=Combi
▪ 1=Heating only + external domestic
hot water tank
▪ 2=Domestic hot water only (no
heating system required)
▪ 3=Heating only
It is recommended not to modify this
setting.
Space heating pump continuous 0~3 0 ▪ 0=Post purge period only
▪ 1=Pump continuously active
▪ 2=Pump continuously active with
MIT switch
▪ 3=Pump on with external switch
This setting has no effect.
Содержание
- Daikin altherma h hybrid gas boiler module p.1
- Installation and operation manual p.1
- Ehy2komb28aa ehy2komb32aa p.1
- Ehy2komb28aa ehy2komb32aa p.2
- Director p.2
- Daikin tcf red 04 p.2
- Daikin tcf gar 01 p.2
- Daikin europe n v p.2
- Boiler efficiency 92 42 eec p.2
- Radio equipment 2014 53 eu p.2
- P369568 6j p.2
- Ostend 14th of march 2019 p.2
- Low voltage 2014 35 eu p.2
- Kiwa nb0063 p.2
- Installation and operation manual p.2
- Hiromitsu iwasaki p.2
- Gr0508 p.2
- Gas appliance regulation 2016 426 eu p.2
- En15502 1 2012 a1 2015 en60335 2 102 2016 en55014 1 2017 en55014 2 2015 en61000 3 2 2014 en61000 3 3 2013 etsi en300220 1 v3 etsi en300220 2 v3 p.2
- Benchmark places responsibilities on both manufacturers and installers the purpose is to ensure that customers are provided with the correct equipment for their needs that it is installed commissioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the p.3
- About the units and options 9 p.3
- About the product 3 p.3
- Troubleshooting 35 p.3
- About the product p.3
- The benchmark scheme p.3
- About the documentation 4 p.3
- Technical data 38 p.3
- About the box 8 p.3
- Table of contents p.3
- Operation 31 p.3
- Maintenance and service 32 p.3
- Installation 12 p.3
- Glossary 37 p.3
- General safety precautions 4 p.3
- Especially for uk p.3
- Disposal 45 p.3
- Configuration 25 p.3
- Commissioning 32 p.3
- General safety precautions p.4
- About this document p.4
- About the documentation p.4
- Meaning of warnings and symbols p.4
- Installation site p.5
- General safety precautions p.5
- General p.5
- For the installer p.5
- General safety precautions p.6
- Electrical p.6
- Local legislation p.7
- General safety precautions p.7
- Gas exhaust p.7
- To unpack the gas boiler p.8
- To remove the accessories from the gas boiler p.8
- Symbols on the package p.8
- Gas boiler p.8
- About the box p.8
- About the units and options p.9
- Possible options for the gas boiler p.9
- Identification label gas boiler p.9
- Identification p.9
- Combining units and options p.9
- About the units and options p.10
- About the units and options p.11
- To open the switch box cover of the gas boiler p.12
- To open the gas boiler p.12
- To install the gas boiler p.12
- Opening the unit p.12
- Mounting the gas boiler p.12
- Installation space requirements p.12
- Installation space p.12
- Installation p.12
- To install the condensate trap p.13
- Installation p.13
- To connect the water piping for domestic hot water not applicable for switzerland p.14
- Internal connections p.14
- Installation p.14
- External connections p.14
- Connecting water piping p.14
- Connecting the water piping of the gas boiler p.14
- Condensate pump p.14
- Condensate pipe work p.14
- To fill the domestic water circuit of the gas boiler p.15
- To connect the water piping for space heating p.15
- To connect the water piping for domestic hot water applicable for switzerland p.15
- Installation p.15
- Flow resistance graph for appliance domestic hot water circuit p.15
- Connecting the electrical wiring p.15
- Installation p.16
- Connecting the gas piping p.16
- To connect the main power supply of the gas boiler p.16
- To connect the gas pipe p.16
- To connect the electrical wiring to the gas boiler p.16
- To change the gas boiler to 80 125 concentric connection p.17
- To change the 60 100 concentric connection to a dual pipe connection p.17
- Installation p.17
- Connecting the boiler to the flue gas system p.17
- Installation p.18
- Calculate the total piping length p.18
- Appliance categories and pipe lengths p.18
- Installation p.19
- Installation p.20
- Installation p.21
- Flue pipe position p.21
- Applicable materials p.21
- Fitting a horizontal flue system p.22
- Plume management kit p.22
- Insulation of the gas exhaust and air intake p.22
- Installation p.22
- Fitting a vertical flue system p.22
- Installation p.23
- Flues in voids p.23
- Flue gas materials c63 available on the market p.23
- About securing the flue system p.23
- Installation p.24
- 3 50 mm m p.24
- 1000 mm p.24
- Overview configuration p.25
- Gas boiler p.25
- Finishing the gas boiler installation p.25
- Configuration p.25
- Basic configuration p.25
- To turn on off the gas boiler p.25
- To perform an air purge on the gas supply p.25
- To install the cover plate p.25
- To close the gas boiler p.25
- To set the parameters via the service code p.26
- To reset the gas boiler p.26
- Maximum space heating supply temperature p.26
- Keep hot function p.26
- Frost protection function p.26
- Domestic hot water temperature p.26
- Domestic hot water comfort function p.26
- Configuration p.26
- Configuration p.27
- Maximum space heating power setting p.28
- Frost protection function p.28
- Configuration p.28
- To change to a different type of gas p.29
- Configuration p.29
- About the co ₂ setting p.29
- Configuration p.30
- Overview operation p.31
- Operation modes p.31
- Operation p.31
- Heating p.31
- Domestic hot water p.31
- To perform a test run on the gas boiler p.32
- To perform a gas pressure test p.32
- To disassemble the gas boiler p.32
- Opening the gas boiler p.32
- Maintenance safety precautions p.32
- Maintenance and service p.32
- Commissioning p.32
- Maintenance and service p.33
- To clean the inside of the gas boiler p.34
- To assemble the gas boiler p.34
- Maintenance and service p.34
- Troubleshooting p.35
- Symptom the burner ignites noisily p.35
- Symptom the burner does not ignite p.35
- Solving problems based on symptoms p.35
- Precautions when troubleshooting p.35
- General guidelines p.35
- Symptom no domestic hot water p.36
- Symptom hot water does not reach the temperature tank installed p.36
- Symptom hot water does not reach the temperature no tank installed p.36
- Solving problems based on error codes p.36
- Error codes overview p.36
- Error codes of the gas boiler p.36
- Troubleshooting p.36
- Symptom the power is reduced p.36
- Symptom the burner resonates p.36
- Symptom space heating does not reach the temperature p.36
- Symptom no space heating by the gas boiler p.36
- Glossary p.37
- Technical data p.38
- Components gas boiler p.38
- Components p.38
- Bottom view p.38
- A subset of the latest technical data is available on the regional daikin website publicly accessible the full set of latest technical data is available on the daikin business portal authentication required p.38
- Wiring diagram p.39
- Technical specifications gas boiler p.39
- Technical specifications p.39
- Technical data p.39
- General p.39
- Wiring diagram gas boiler p.39
- Technical data p.40
- Energy related products specifications p.40
- Technical data p.41
- Gas category and supply pressure p.41
- Technical data p.42
- This commissioning checklist is to be completed in full by the competent person who commissioned the boiler as a means of demonstrating compliance with the appropriate building regulations and then handed to the customer to keep for future reference p.43
- Technical data p.43
- Installation and operation manual p.43
- Gas boiler system commissioning checklist p.43
- Ehy2komb28 32aa daikin altherma h hybrid gas boiler module 4p538953 1a 2020 2 p.43
- Service 01 p.44
- P538953 1a 2020 2 p.44
- Installation and operation manual p.44
- Ehy2komb28 32aa p.44
- Daikin altherma h hybrid gas boiler module p.44
- Technical data p.44
- Service record p.44
- Service 10 p.44
- Service 09 p.44
- Service 08 p.44
- Service 07 p.44
- Service 06 p.44
- Service 05 p.44
- Service 04 p.44
- Service 03 p.44
- Service 02 p.44
- Disposal p.45
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
Узнайте о функциях и настройках газового котла, включая комфорт горячей воды, защиту от замерзания и параметры работы. Подробная инструкция для пользователей.