Icom IC-PCR1000 [11/16] Panel description
![Icom IC-PCR1000 [11/16] Panel description](/views2/1074686/page11/bgb.png)
2
PANEL DESCRIPTION
8
@3 DELAY TIME scroll bar
This sets the period in which a scan pauses after receiving a
signal. Moving the knob to the right increases the period; to
the left decreases the period.
@4 SPEED (scan speed) scroll bar
Sets the speed at which scans search through frequen-
cies/memories for signals. Moving the knob to the right in-
creases the speed; to the left decreases the speed.
@5 VSC (Voice Scan Control) button
Turns the voice scan control function on and off. This function
detects whether signals are modulated (contain voice or
music components, etc.) or not.
@6 AF (audio frequency) GAIN scroll bar
Adjusts the audio output.
@7 MUTE button
Turns the mute function on and off. Used to temporarily mute
audio output.
@8 SQUELCH scroll bar
Adjusts the squelch level.
@9 MONI (Monitor) button
Turns the monitor function on and off. The monitor function is
used to temporarily open the squelch to listen to weak sig-
nals.
#0 ATT (Attenuator) button
Turns the attenuator on and off.
#1 AGC (Automatic Gain Control) button
Turns the AGC function on and off.
#2 NB (Noise Blanker) button
Turns the noise blanker function on and off. The noise blanker
is used to reduce pulse type noise.
#3 AFC (Automatic Frequency Control) button
Turns the AFC function on and off. This function tracks the re-
ceive signal when drifting.
#4 Center button
After moving a signals’ passband position with the [IF-SHIFT]
scroll bar, this button returns it to the center position.
#5 IF-SHIFT (IF shift) scroll bar
Sets a signals passband position. Moving the knob to the
right sets the passband higher, moving the knob to the left
sets the passband lower.
#6 FILTER (IF filter) buttons
Change the IF filter in use. The [WIDE] button selects a wider
filter, the [NAR] button selects a narrower filter.
- Usable IF filters vary according to receive mode.
#7 T (Tone squelch) button
Shows/hides the [TONE SQUELCH] dialog box for setting
tone squelch tone frequencies.
#8 Receive mode buttons
Select a receive mode. Using the [AUT-M] button to select au-
tomatic mode also selects a receive mode.
Содержание
- Communications receiver for computer 1
- Instruction manual 1
- Ipcr1000 1
- Features 2
- Important 2
- Read all instruction 2
- Save this instruction manual 2
- System requirements 2
- Allow children to touch the receiver 3
- Caution 3
- Cautions 3
- Class b digital device users 3
- Connect other than the specified ac adapter to the receiver this connection will ruin the receiver 3
- Connect the receiver to a power source of more than 16 v dc such as a 24 v battery this connection will ruin the receiver 3
- Connect the receiver to an ac outlet this may pose a fire hazard or result in an electric shock 3
- Expose the receiver to rain snow or any liquids 3
- For canada only 3
- For u s a only fcc information 3
- Placing the receiver in excessively dusty environ ments 3
- R warning neve 3
- The use of chemical agents such as benzine or al cohol when cleaning as they damage the receiver surfaces 3
- Use or place the receiver in areas with tempera tures below 0 c 32 f or above 50 c 122 f or in areas subject to direct sunlight 3
- I hardware installation 4
- Installation 4
- Caution 5
- I antenna installation 5
- I grounding 5
- Installation 5
- R warning neve 5
- I af output level selection 6
- Installation 6
- I tnc connection 7
- Installation 7
- D on line help information 8
- D software update information 8
- D windows 3 8
- D windows 95 8
- I serial port setting 8
- I software installation 8
- Installation 8
- I component screen 9
- Panel description 9
- Panel description 10
- Panel description 11
- Panel description 12
- I communications receiver screen 13
- I radio screen 13
- Panel description 13
- Frequency coverage mhz u s a 00 0 10000 823 99999 849 00001 868 99999 894 00001 1300 00000 europe 00 0 10000 1300 00000 14
- Frequency mhz 14
- Frequency mhz ssb cw am fm wfm 14
- Receive sensitivity typical 14
- Specifications and unpacking 14
- Squelch sensitivity threshold 14
- Ssb cw 14
- I unpacking 15
- Specifications and unpacking 15
- 9 16 kamihigashi hirano ku osaka 547 0002 japan 16
Похожие устройства
- Asko C9535 A42002022 RU WHITE FS 50 Инструкция по эксплуатации
- Siemens KG36EAL20R Инструкция по эксплуатации
- Icom IC-R1500 Инструкция по эксплуатации
- Bosch KGE36AI20R Инструкция по эксплуатации
- Asko C9540 A42002017 RU WHITE FS 50 Инструкция по эксплуатации
- Icom IC-PCR1500 Инструкция по эксплуатации
- Bosch KGE39AW30R Инструкция по эксплуатации
- Asko C9545 A42002025 RU WHITE FS 50 Инструкция по эксплуатации
- Icom IC-PCR2500 Инструкция по эксплуатации
- Siemens KG39EAL20R Инструкция по эксплуатации
- Asko C955 A527C52A RU WHITE FS 50 Инструкция по эксплуатации
- Icom IC-R2 Инструкция по эксплуатации
- Siemens KG39EAW30R Инструкция по эксплуатации
- Asko C9555 A42002023 RU WHITE FS 50 Инструкция по эксплуатации
- Icom IC-R2500 Инструкция по эксплуатации
- Bosch KGE39AI20R Инструкция по эксплуатации
- Asko C9560 A42002018 RU WHITE FS 50 Инструкция по эксплуатации
- Icom IC-R3 Инструкция по эксплуатации
- Asko C958 A559C62A RU WHITE FS 60 Инструкция по эксплуатации
- Icom IC-R5 Инструкция по эксплуатации