Daikin 5MXS90E7V3B [51/73] Capacity tables

Daikin 5MXS90E7V3B [51/73] Capacity tables
Outdoor Units R410A MXS-DAVMB_E2V1B_E7V3B
1
5
Split Sky Air Outdoor Units51
5 Capacity tables
5 - 1 Combination table
Cooling [50Hz 230V]
Outdoor unit Combination of
indoor unit
Capacity of each indoor unit
Each capacity (kW) Total capacity (kW)
Total input (W)
Total current (A) Power factor %
A Room B Room C Room D Room ERoom Rating
(Min.max.)
Rating
(Min.max.)
Rating
(Min.max.) Rating
3D052435-1A
NOTES
1 Cooling capacity is based on 27°CDB / 19°CWB (indoor temperature), 35°CDB (outdoor temperature).
Heating capacity is based on 20°CDB (indoor temperature), 7°CDB/6°CWB (outdoor temperature).
2 The total ability of connected a indoor unit is up to 15.6 kW
3 It is impossible to connect the indoor unit for one room only.
4 The above is the value for connecting with the following indoor units.
2.0, 2.5, 3.5 kW class: wall mounted C series
5.0, 6.0, 7.1 kW class: wall mounted E series