Daikin RKS60E3V1B [122/150] Disconnect the 2 earth wires

Daikin RXS60E3V1B [122/150] Disconnect the 2 earth wires
Outdoor Unit SiBE07-618_D
112 Removal Procedure
4
Disconnect the 2 earth
wires.
5
Remove the 3 screws
of the right side panel.
6
Remove the screw of
the electrical box.
Step
Procedure Points
Earth wires
(R5269)
(R5270)
Right
side
panel