Karcher WPC 2500 SW [18/36] Troubleshooting
![Karcher WPC 2500 SW [18/36] Troubleshooting](/views2/1007822/page18/bg12.png)
18 English
The LEDs on the operating panel and on
the display will show the interruptions in the
RO plant.
Note
If there is an interruption, the plant gets
switched off automatically and the drinking
water production is interrupted. If the prob-
lem cannot be rectified, switch off the plant
and inform Kärcher Customer Service.
Î If the system does not start in automatic
mode, interrupt the power supply. The
controls will get reset.
Î Rectify other faults according to the de-
tails provided in the following tables.
Troubleshooting
Interruptions in the RO plant
Description /
Display
Cause Remedy
LED General fault, details - see display.
CD max Permeate index value too high. Acknowledge with fault key, notify customer service if
necessary.
Display Stop Active carbon or media filter is cleaned. Wait for cleaning process, the system will start auto-
matically
Power failure,
set clock
Power supply was interrupted. Acknowledge with fault key.
CD Permeate
max
Permeate index value too high. Inform Customer Service.
CD Permeate
min
Index value probe is defective. Inform Customer Service.
Low water pres-
sure
Fine filter blocked. Replace, acknowledge with fault key.
Raw water inflow interrupted. Reestablish the raw water inflow, notify customer
service if necessary.
Pressure switch is defective. Inform Customer Service.
Motor protection High-pressure pump defective. Inform Customer Service.
Dosing container is empty Fill dosing container and then acknowledge the fault.
Exceed range
CD
Permeate conductivity too high. Inform Customer Service.
Index value probe is defective. Inform Customer Service.
Max Q-flush time Permeate conductivity too high. Inform Customer Service.
Temperature low Room temperature too low. Check the temperature of the erection room, heat if
necessary.
Raw water temperature too low Check the raw water inflow, notify customer service if
necessary.
Interruptions in the dosing stations
Dosing pump transports too
much or too little
Dosing frequency or dosing stroke is displaced. Adjust the dosing frequency or dosing stroke.
Dosing pump does not trans-
port.
Mains plug of the dosing pump not plugged in. Connect the mains plug to the unit.
Plant is not switched on. Switch on plant.
Dosing pump is not deaerated. Bleed dosing pump.
Defective dosing membrane. Inform Customer Service.
Содержание
- Wpc 2500 sw am 1
- Allgemein 4
- Bedienelemente 4
- Bestimmungsgemäße ver wendung 4
- Dosierstation befüllen 4
- Inbetriebnahme 4
- Inhaltsverzeichnis 4
- Sicherheitshinweise 4
- Symbole in der betriebsanleitung 4
- Umweltschutz 4
- Vor inbetriebnahme 4
- Anlage ausschalten 5
- Anlage einschalten 5
- Betrieb 5
- Pflege und wartung 5
- Überwachungselemente 5
- Wartungsarbeiten 6
- Wartungsplan 6
- Verbrauchsmaterial 7
- Hilfe bei störungen 8
- Störungen an den dosierstationen 8
- Störungen an der ro anlage 8
- Ce erklärung 9
- Garantie 9
- Technische daten 9
- Zubehör und ersatzteile 9
- Rückseite bleibt leer damit das blatt herausgetrennt werden kann 12
- Before commissioning 14
- Contents 14
- Control elements 14
- Environmental protection 14
- Filling up the dosing station 14
- General 14
- Proper use 14
- Safety instructions 14
- Start up 14
- Symbols in the operating instruc tions 14
- Maintenance and care 15
- Monitoring elements 15
- Operation 15
- Switching off the plant 15
- Switching on the plant 15
- Maintenance schedule 16
- Maintenance works 16
- Consumables 17
- Interruptions in the dosing stations 18
- Interruptions in the ro plant 18
- Troubleshooting 18
- Accessories and spare parts 19
- Ce declaration 19
- Technical specifications 19
- Warranty 19
- Rear side is kept blank so that the sheet can be separated 22
- Antes de la puesta en marcha 24
- Elementos de mando 24
- General 24
- Indicaciones de seguridad 24
- Protección del medio am biente 24
- Puesta en marcha 24
- Rellenar la estación dosificadora 24
- Símbolos del manual de instruccio nes 24
- Uso previsto 24
- Índice de contenidos 24
- Apagar la instalación 25
- Conectar la instalación 25
- Cuidados y mantenimiento 25
- Elementos de vigilancia 25
- Funcionamiento 25
- Plan de mantenimiento 26
- Trabajos de mantenimiento 26
- Material de uso 28
- Averías en la instalación ro 29
- Averías en las estaciones de dosificación 29
- Ayuda en caso de avería 29
- Accesorios y piezas de re puesto 30
- Datos técnicos 30
- Declaración ce 30
- Garantía 30
- Parte posterior en blanco para separar la hoja 34
Похожие устройства
- Soundmax SM-3221 Инструкция по эксплуатации
- Shturmann Link 500 Инструкция по эксплуатации
- Энкор Корвет-10 10210 Инструкция по эксплуатации
- Line6 POD XT LIVE DIRECT FLOOR GUITAR PREAMPLIFIER Инструкция по эксплуатации
- Karcher WPC 5000 CD Инструкция по эксплуатации
- Bosch WLF20171CE Инструкция по эксплуатации
- Pioneer XDV-P9-II Инструкция по эксплуатации
- AEG 419900 AU 1000 Инструкция по эксплуатации
- Line6 DL4 Инструкция по эксплуатации
- Soundmax SM-3121 Инструкция по эксплуатации
- Karcher WPC 5000 BW Инструкция по эксплуатации
- Bosch WLX20463OE Инструкция по эксплуатации
- Pioneer XDV-P9 Инструкция по эксплуатации
- Line6 FM4 Инструкция по эксплуатации
- Soundmax SM-3111 Инструкция по эксплуатации
- Jet JTS-315SP 10000910SM Инструкция по эксплуатации
- Sony MDRZX300B Инструкция по эксплуатации
- Bosch WAE 28443 OE Инструкция по эксплуатации
- Jet JWL-1440L PERFORMAX 10000750M Инструкция по эксплуатации
- Sony MDRZX100B Инструкция по эксплуатации