Daikin EHVH04SU18CB6W [52/108] Quick wizard options
8 Configuration
Installer reference guide
52
ERLQ004~008CA + EHVH04+08SU18+26CB6W
Daikin Altherma – Low temperature split
4P449978-1 – 2016.06
# Code Description
[A.2.1.8] [7-02] << continuation
1 (2 LWT zones): 2 leaving water
temperature zones. The zone with the
lowest leaving water temperature (in
heating) is called the main leaving
water temperature zone. The zone
with the highest leaving water
temperature (in heating) is called the
additional leaving water temperature
zone. In practice, the main leaving
water temperature zone consists of
the higher load heat emitters and a
mixing station is installed to achieve
the desired leaving water temperature.
a
b
a: Add LWT zone
b: Main LWT zone
# Code Description
[A.2.1.9] [F-0D] When the space heating control is OFF
by the user interface, the pump is always
OFF. When the space heating control is
On, you can select the desired pump
operation mode (only applicable during
space heating)
Pump operation mode:
0 (Continuous): Continuous pump
operation, regardless of thermo ON or
OFF condition. Remark: continuous
pump operation requires more energy
than sample or request pump
operation.
a
b c
d
b c
a: Space heating control (user
interface)
b: OFF
c: On
d: Pump operation
continued >>
# Code Description
[A.2.1.9] [F-0D] << continuation
1 (Sample): The pump is ON when
there is heating demand and the
leaving water temperature has NOT
reached the desired temperature yet.
When thermo OFF condition occurs,
the pump runs every 5 minutes to
check the water temperature and
demand heating if necessary.
Remark: Sample is NOT available in
external room thermostat control or
room thermostat control.
a
b
d
e
f
c
g
b
c
a: Space heating control (user
interface)
b: OFF
c: On
d: LWT temperature
e: Actual
f: Desired
g: Pump operation
continued >>
# Code Description
[A.2.1.9] [F-0D] << continuation
2 (Request)(default): Pump operation
based on request. Example: Using a
room thermostat creates thermo ON/
OFF condition. When there is no such
demand, the pump is OFF. Remark:
Request is NOT available in leaving
water temperature control.
a
d
e
b
b
c
b c
c
a: Space heating control (user
interface)
b: OFF
c: On
d: Heating demand (by ext RT or
RT)
e: Pump operation
8.2.3 Quick wizard: Options
Domestic hot water settings
Following settings must be made accordingly.