Daikin EHVH04SU18CB6W [92/108] Technical data

Превью страниц Страница 92 / 108
Daikin EHVH08SU18CB6W [92/108] Technical data
14 Technical data
Installer reference guide
92
ERLQ004~008CA + EHVH04+08SU18+26CB6W
Daikin Altherma – Low temperature split
4P449978-1 – 2016.06
English Translation
Outdoor unit Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
Preferential kWh rate power
supply contact: 16VDC
detection (voltage supplied by
PCB)
Use normal kWh rate power
supply for indoor unit
Use normal kWh rate power
supply for indoor unit
(2) Backup heater power supply (2) Backup heater power supply
(3) User interface (3) User interface
Only for remote user interface
option
Only for remote user interface
option
Switch box Switch box
(4) Ext. thermistor (4) External thermistor
Switch box Switch box
(5) Field supplied options (5) Field supplied options
230 V AC supplied by PCB 230VAC supplied by PCB
5 V DC pulse detection (voltage
supplied by PCB)
5VDC pulse detection (voltage
supplied by PCB)
Continuous Continuous current
DHW pump Domestic hot water pump
DHW pump output Domestic hot water pump output
Electrical meters Electrical meters
For safety thermostat For safety thermostat
Inrush Inrush current
Max. load Maximum load
Normally closed Normally closed
Normally open Normally open
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Safety thermostat contact:
16VDC detection (voltage
supplied by PCB)
Shut-off valve Shut-off valve
Switch box Switch box
(6) Booster heater power supply (6) Booster heater power supply
English Translation
(7) Option PCBs (7) Option PCBs
Alarm output Alarm output
Changeover to ext. heat source Changeover to external heat
source
Max. load Maximum load
Min. load Minimum load
Only for *** Only for ***
Only for demand PCB option Only for demand PCB option
Only for digital I/O PCB option Only for digital I/O PCB option
Only if no *** Only if no ***
Options: boiler output, alarm
output
Options: boiler output, alarm
output
Options: bottom plate heater OR
On/OFF output
Options: bottom plate heater OR
On/OFF output
Outdoor unit Outdoor unit
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Power limitation digital inputs:
12VDC / 12mA detection
(voltage supplied by PCB)
Space C/H On/OFF output Space cooling/heating On/OFF
output
Switch box Switch box
To bottom plate heater To bottom plate heater
(8) External On/OFF thermostats
and heat pump convector
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone Additional leaving water
temperature zone
Main LWT zone Main leaving water temperature
zone
Only for external sensor (floor/
ambient)
Only for external sensor (floor or
ambient)
Only for heat pump convector Only for heat pump convector
Only for wired thermostat Only for wired thermostat
Only for wireless thermostat Only for wireless thermostat