Daikin EHVH04SU18CB6W [86/108] Technical data

Превью страниц Страница 86 / 108
Daikin EHVH04SU18CB6W [86/108] Technical data
14 Technical data
Installer reference guide
86
ERLQ004~008CA + EHVH04+08SU18+26CB6W
Daikin Altherma – Low temperature split
4P449978-1 – 2016.06
14 Technical data
A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is
available on the Daikin extranet (authentication required).
14.1 Components and dimensions: Indoor unit
EHVH_SU18 (dimensions in mm)
EKVSU180*
3D106601-1
151
251 275
307
346 49
20
115
245
32
59
66
728
760
69
600
R210
28
60
954 419
300>
1733
1745
1760
408
l ab k g j f i g
dd
aa
r
n
e
d
q
o
w
t
p
c
cc
x
y
oo
u
h
dd
v
m
s
bb
a Gas pipe connection (Ø15.9mm flare)
b Liquid pipe connection (Ø6.4mm flare)
c Manometer
d Safety valve
e Drain valve water circuit
f Air purge
g Shut-off valve with drain/fill valve (delivered as accessory)
h Water filter
i Space heating water IN (1-1/4" F BSP)
j Space heating water OUT (1-1/4" F BSP)
k Domestic hot water: cold water IN (3/4" M BSP)
l Domestic hot water: hot water OUT (3/4" F BSP)
m Low voltage wiring intake (Ø24mm)
n High voltage wiring intake (power supply + control signal)
(Ø24mm)
o Levelling feet
p User interface (option kit)
q Drain valve domestic hot water tank circuit
r Recirculation connection (G 1/2" female)
s Hole for the recirculation piping or options wiring (Ø35mm)
t Drain outlet
u Expansion vessel (10l with a factory-set pre-pressure of
1bar)
v 3-way valve
w Pressure relief valve (15mm male; factory-fitted;
replacement part number = 302810P)
x Tundish (22-15mm)
y Discharge to a trapped gully, below a fixed grating
Components in domestic hot water tank kit (EKVSU180A):
aa Pressure reducing valve (22-22mm)
bb Pressure relief valve (15mm)
cc Tundish (22-15mm)
dd Expansion vessels (5l + 5l with a factory-set pre-pressure
of 2.5bar)