Daikin FWXM10AATV3 [4/20] General
![Daikin FWXM10AATV3 [4/20] General](/views2/1786259/page4/bg4.png)
4
1.1
1.2
General warnings
Fundamental safety rules
After unpacking, make sure that all the components
are present. If not, contact your installer of your DAIKIN
affiliate office.
DAIKIN appliances must be installed by an authorised
installer who, on completion of the work, will release a
declaration of conformity to the client in respect of the
laws in force and the indications given by DAIKIN in the
instructions leaflet supplied together with the appliance.
These appliances have been designed both for
conditioning and/or heating environments and must
be destined for this use only and compatibly with their
performance characteristics.
DAIKIN EUROPE N.V. accepts no responsibility, either
contractual or extra-contractual, for any damage caused
to persons, animals of property as a result of incorrect
installation, adjustment or maintenance or improper use.
In case of water leaks, turn the master switch of the
system to "OFF" and close the water taps.
As soon as possible, call the DAIKIN technical service
department or else professionally qualified personnel
and do not intervene personally on the appliance.
The imbedded FWXM-series do not have a grill or
covering plate. Provide safety guards and air inlet/outlet
grills to prevent accidental contact with the device.
If the appliance is not used for a log period of time, the
following operations should be performed:
- Turn the master switch of the system to "OFF"
- Close the water taps
- If there is the risk of freezing, make sure that anti-freeze
has been added to the system otherwise empty the
system.
If the room temperature is too low or too high it is
damaging for the health and is also a useless waste of
energy.
Avoid prolonged contact with the direct air flow.
Do not leave the room closed for long periods.
Periodically open the windows to ensure a correct
change of air.
This instruction leaflet is an integral part of the
appliance and consequently must be kept carefully
and must ALWAYS accompany the appliance, even
when it is passed to a new owner or user or transferred
onto another system. If it is lost or damaged, please
contact the local DAIKIN technical service centre.
All repair or maintenance interventions must be
performed by the technical service department or by
professionally qualified personnel as foreseen in this
booklet. Do not modify or intervene on the appliance
as this could create dangerous situations and the
manufacturer will not be responsible for any damage
caused.
Danger from burns - take care when touching
Remember that some fundamental safety rules should
be followed when using a product that uses electricity
and water, such as:
The unit can be used by children over the age of
8, and by people with reduced physical, sensory or
mental capabilities, or with no experience or necessary
knowledge, as long as they are monitored or after they
have received instructions on the safe use of the unit
and have understood the dangers involved.
Children must not play with the appliance.
The cleaning and maintenance that must be
performed by the user should not be carried out by
children without supervision.
It is forbidden to touch the appliance with wet hands
or body when barefoot.
It is forbidden to carry out any cleaning before having
disconnected the appliance from the electricity mains
supply by turning the system master switch to "OFF".
It is forbidden to modify the safety or adjustment
devices or adjust without authorisation and indications
of the manufacturer.
It is forbidden to pull, cut or knot the electrical cables
coming out of the appliance, even if it is disconnected
from the mains supply.
GENERAL
Содержание
- Daikin altherma 1
- Heat pump convector 1
- Installation manual 1
- By following the suggestions contained in this manual the water water heat pump that you have purchased will operate without problems giving you optimum room temperatures with minimum energy costs 2
- Conformity 2
- Daikin europe n v 2
- Symbols 2
- We are sure you will be happy with it because it represents the state of the art in the technology of home air conditioning 2
- We would first of all like to thank you for having chosen one of our products 2
- General 3
- Installation 3
- Troubleshooting 3
- Fundamental safety rules 4
- General 4
- General warnings 4
- Fwxm series 5
- Fwxv series 5
- Nominal technical features 5
- Product range 5
- Overall dimensions heat pump convector 6
- Installation 7
- Installation modes 7
- Minimum installation distances 7
- Mm 20 mm 7
- Positioning the unit 7
- Access to the body machine 8
- Remove side 9
- Vertical floor or wall installation fwxv series 9
- Horizontal or ceiling installation fwxm series 10
- Hydraulic connections 10
- Condensation discharge 11
- Mounting the condensation discharge pipe in the vertical version 11
- Evacuating air while filling the system 12
- Filling the system 12
- Mounting the condensation discharge pipe in the horizontal version fwxm series 12
- Cleaning the outside 13
- Electrical connections 13
- Maintenance 13
- Cleaning air suction filter 14
- Extraction of filter cells 14
- Cleaning filtering seats 15
- Ending cleaning operations 15
- Energy saving tips 15
- Table of anomalies and remedies 16
- Troubleshooting 16
Похожие устройства
- Daikin FWXM15AATV3 Инструкция по монтажу
- Daikin FWXM20AATV3 Инструкция по монтажу
- Daikin EHSX04P30A Руководство по применению для пользователя
- Daikin EHSX04P30A Руководство по эксплуатации
- Daikin EHSX04P30A Инструкция по монтажу
- Daikin EHSXB04P30A Руководство по применению для пользователя
- Daikin EHSXB04P30A Руководство по эксплуатации
- Daikin EHSXB04P30A Инструкция по монтажу
- Daikin EHSX08P30A Руководство по применению для пользователя
- Daikin EHSX08P30A Руководство по эксплуатации
- Daikin EHSX08P30A Инструкция по монтажу
- Tecnoclima DGK 65 Инструкция по эксплуатации
- Tecnoclima DGK 65 Сертификат
- Tecnoclima DGK 65 Каталог
- Tecnoclima DGK 115 Инструкция по эксплуатации
- Tecnoclima DGK 115 Сертификат
- Tecnoclima DGK 115 Каталог
- Tecnoclima DGS 40 Инструкция по эксплуатации
- Tecnoclima DGS 40 Сертификат
- Tecnoclima DGS 40 Каталог