Daikin EHSX04P30A — установка и обслуживание систем отопления и кондиционирования [13/68]

Превью страниц Страница 13 / 68
Daikin EHSHB08P50A [13/68] Set up and installation
3 x Set-up and installation
Daikin Altherma EHS(X/H)
Daikin Solar tank with integrated interior heat pump unit
008.1420744 – 06/2015
Installation and maintenance manual
13
3 Set-up and installation
WARNING
Cooling systems (heating pumps), climate co
ntrol systems and heating devices that have been set up and installed incor-
rectly can both endanger life and health of peop
le and be impaired in their function.
Work on the Dai
kin Altherma EHS(X/H) (such as setup, servicing, connection and initial start-up) is only to be carried
out by persons who are authorised and who have successfully completed qualifying technical or vocational training
and who have taken part in advanced training sessions recognised by the relevant responsible authorities for the
specific activity. These include in particular certified heating engineers, qualified electricians and HVAC
specialists, who because of their professional training and expert knowledge, have experience in the professional
installation and maintenance of heating, cooling and air conditioning systems and heat pumps.
3.1 Dimensions and connections
3.1.1 Daikin Altherma EHS(X/H)...P30A
1 Solar - feed
2 Cold water
3 Hot water
4 Heating feed
5 H
eating return flow
6 Connection coolant gas line
7 Connection coolant fluid line
8
Solar - feed flow (only Type ... Altherma EHS(X/H)B)
9
Solar - return (only Type ... Altherma EHS(X/H)B)
A Front
BBack
Fig. 3-1 Connections and dimensio
ns Daikin Altherma EHS(X/H)...P30A (general)

Содержание

257

Правильная установка и обслуживание систем отопления и кондиционирования жизненно важны для безопасности и эффективности. Узнайте о требованиях и рекомендациях для специалистов.