Daikin EHSXB08P50A — установка и обслуживание тепловых насосов и солнечных систем [3/68]
Превью страниц
Страница 3 /
68
![Daikin EHSHB04P30A [3/68] Malfunctions 43](/views2/1786267/page3/bg3.png)
List of contents
Daikin Altherma EHS(X/H)
Daikin Solar tank with integrated interior heat pump unit
008.1420744 – 06/2015
Installation and maintenance manual
3
1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1 Observing instructions . . . . . . . . . . . . . . . . . . . .4
1.2 Warning signs and explanation of symbols. . . . .4
1.2.1 Meaning of the warnings . . . . . . . . . . . . . . . . . . . . 4
1.2.2 Validity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2.3 Handling instructions . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 Avoid danger. . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.4 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.5 Instructions for operating safety . . . . . . . . . . . . .5
1.5.1 Before working on the hydraulic system . . . . . . . . 5
1.5.2 Electrical installation . . . . . . . . . . . . . . . . . . . . . . . 5
1.5.3 Working on cooling systems (heat pump) . . . . . . . 6
1.5.4 Site of installation . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.5.5 Heating system and sanitary connection. . . . . . . . 6
1.5.6 Requirements for the heating water . . . . . . . . . . . 6
1.5.7 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.5.8 Instructing the user/owner . . . . . . . . . . . . . . . . . . . 6
2 Product description . . . . . . . . . . . . . . . . . . . 7
2.1 Design and components . . . . . . . . . . . . . . . . . . .7
2.1.1 Top of unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1.2 Device external and internal design
Daikin Altherma EHS(X/H)...P30A . . . . . . . . . . . . 8
2.1.3 Device external and internal design
Daikin Altherma EHS(X/H)B...P30A . . . . . . . . . . . 9
2.1.4 Device external and internal design
Daikin Altherma EHS(X/H)...P50A . . . . . . . . . . . 10
2.1.5 Device external and internal design
Daikin Altherma EHS(X/H)B...P50A . . . . . . . . . . 11
3 Set-up and installation . . . . . . . . . . . . . . . . 13
3.1 Dimensions and connections . . . . . . . . . . . . . .13
3.1.1 Daikin Altherma EHS(X/H)...P30A . . . . . . . . . . . 13
3.1.2 Daikin Altherma EHS(X/H)...P50A . . . . . . . . . . . 14
3.1.3 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2 Set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
3.3 Water connection . . . . . . . . . . . . . . . . . . . . . . .16
3.3.1 Connecting hydraulic lines . . . . . . . . . . . . . . . . . 17
3.4 Electrical connection . . . . . . . . . . . . . . . . . . . . .17
3.4.1 Overall connection plan Daikin Altherma
EHS(X/H). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.4.2 Position of the circuit boards . . . . . . . . . . . . . . . . 19
3.4.3 Connection assignment, circuit board A1P . . . . . 19
3.4.4 Terminal assignment for the RTX-AL4
circuit board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.4.5 Terminal assignment for the RTX-EHS
circuit board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.4.6 Connection assignment, circuit board
RoCon BM1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.4.7 Mains connection Daikin Altherma EHS(X/H) . . . 20
3.4.8 Removing the protective cover . . . . . . . . . . . . . . 20
3.4.9 Opening the control housing and establishing
electrical connections . . . . . . . . . . . . . . . . . . . . . 21
3.4.10 Connection of ERLQ exterior heat pump unit . . . 21
3.4.11 Connection of external temperature sensor
RoCon OT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.4.12 Connection of an external switching contact . . . . 22
3.4.13 External demand signal (EDS) . . . . . . . . . . . . . . 22
3.4.14 Connection of the electrical Daikin backup
heater (EKBUxx) . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.4.15 Connection of an external heat generator . . . . . . 23
3.4.16 Connection of the Daikin room thermostat . . . . . 25
3.4.17 Connection optional Daikin RoCon system
components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.4.18 Connection of the Daikin FWXV(15/20)AVEB. . . 26
3.4.19 Connection switch contacts (AUX outputs) . . . . . 26
3.4.20 Low tariff mains connection (HT/NT) . . . . . . . . . . 26
3.4.21 Connection intelligent controller
(Smart Grid - SG). . . . . . . . . . . . . . . . . . . . . . . . . 27
3.4.22 Symbols and legend keys on connection and
circuit diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.5 Laying coolant lines . . . . . . . . . . . . . . . . . . . . . 29
3.6 Pressure test and filling the coolant circuit. . . . 30
3.7 Filling the system with water . . . . . . . . . . . . . . 30
3.7.1 Checking the water quality and adjusting
the pressure gauge . . . . . . . . . . . . . . . . . . . . . . . 30
3.7.2 Filling the hot water heat exchanger . . . . . . . . . . 30
3.7.3 Filling the storage tank . . . . . . . . . . . . . . . . . . . . 30
3.7.4 Filling the heating system . . . . . . . . . . . . . . . . . . 30
4 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.1 Initial commissioning . . . . . . . . . . . . . . . . . . . . 31
4.1.1 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.1.2 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.1.3 Set the commissioning parameters . . . . . . . . . . . 31
4.1.4 Venting the internal heating circulation pump . . . 32
4.1.5 Activating the Parameter [Air Purge] . . . . . . . . . . 33
4.1.6 Check minimum flow . . . . . . . . . . . . . . . . . . . . . . 33
4.1.7 Configuring Screed Program parameters
(only if necessary) . . . . . . . . . . . . . . . . . . . . . . . . 33
4.2 Re-commissioning . . . . . . . . . . . . . . . . . . . . . . 33
4.2.1 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
4.2.2 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5 Decommissioning. . . . . . . . . . . . . . . . . . . . 35
5.1 Temporary shutdown . . . . . . . . . . . . . . . . . . . . 35
5.1.1 Draining the storage tank . . . . . . . . . . . . . . . . . . 35
5.1.2 Draining the heating circuit and hot water circuit . 36
5.2 Final shutdown. . . . . . . . . . . . . . . . . . . . . . . . . 37
6 Service and maintenance. . . . . . . . . . . . . . 38
6.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.2 Removing the protective cover . . . . . . . . . . . . 38
6.3 Activities to be performed annually . . . . . . . . . 38
6.4 Filling and topping up the storage tank . . . . . . 40
6.5 Filling and topping up the heating system . . . . 41
7 Errors, malfunctions and messages. . . . . 42
7.1 Recognising errors, correcting malfunctions . . 42
7.1.1 Current fault display. . . . . . . . . . . . . . . . . . . . . . . 42
7.1.2 Read Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
7.1.3 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . 42
7.2 Malfunctions. . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7.3 Fault codes . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
7.4 Monitoring and configuration DIP Switch . . . . . 53
7.5 Emergency operation. . . . . . . . . . . . . . . . . . . . 54
8 Hydraulic system connection . . . . . . . . . . 55
9 Technical data. . . . . . . . . . . . . . . . . . . . . . . 58
9.1 Equipment data . . . . . . . . . . . . . . . . . . . . . . . . 58
9.1.1 Daikin Altherma EHS(X/H)...P30A. . . . . . . . . . . . 58
9.1.2 Daikin Altherma EHS(X/H)...P50A. . . . . . . . . . . . 60
9.2 Characteristic lines. . . . . . . . . . . . . . . . . . . . . . 61
9.2.1 Sensor characteristic lines. . . . . . . . . . . . . . . . . . 61
9.2.2 Characteristic curves for pumps . . . . . . . . . . . . . 63
9.3 Tightening torque . . . . . . . . . . . . . . . . . . . . . . 63
9.4 Circuit diagram Daikin Altherma EHS(X/H) . . . 64
10 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
11 List of keywords . . . . . . . . . . . . . . . . . . . . . 67
Содержание
257- Indoor unit for air water heat pumps daikin altherma integrated solar unit
- Installation and maintenance manual
- Malfunctions 43
- Tightening torque 63
- Emergency operation 54
- Temporary shutdown 35
- List of keywords 67
- Electrical connection 7
- Technical data 58
- List of contents
- Dimensions and connections 3
- Start up 31
- Laying coolant lines 29
- Design and components
- Set up and installation 13
- Intended use
- Decommissioning 35
- Set up 5
- Instructions for operating safety
- Circuit diagram daikin altherma ehs x h 64
- Service and maintenance 38
- Initial commissioning 31
- Characteristic lines 61
- Safety 4
- Hydraulic system connection 55
- Avoid danger
- Removing the protective cover 38
- General 38
- Activities to be performed annually 38
- Recognising errors correcting malfunctions 42
- Final shutdown 37
- Filling the system with water 30
- Re commissioning 33
- Filling and topping up the storage tank 40
- Product description 7
- Filling and topping up the heating system 41
- Pressure test and filling the coolant circuit 30
- Fault codes 47
- Observing instructions
- Errors malfunctions and messages 42
- Water connection 6
- Notes 65
- Warning signs and explanation of symbols
- Monitoring and configuration dip switch 53
- Equipment data 58
- X safety
- Warning signs and explanation of symbols
- Validity
- Special warning signs
- Safety
- Relevant documents
- Observing instructions
- Meaning of the warnings
- Handling instructions
- Intended use
- Instructions for operating safety
- Electrical installation
- Before working on the hydraulic system
- Avoid danger
- X safety
- X safety
- Working on cooling systems heat pump
- Site of installation
- Requirements for the heating water
- Operation
- Instructing the user owner
- Heating system and sanitary connection
- X product description
- Top of unit
- Product description
- Design and components
- X product description
- Fig 2 2 design and components of the daikin altherma ehs x h p30a external view and internal design for legend descriptions see tab 2 1
- Device external and internal design daikin altherma ehs x h p30a
- Device external and internal design daikin altherma ehs x h b p30a
- X product description
- Fig 2 3 design and components of the daikin altherma ehs x h b p30a external view and internal design for legend descriptions see tab 2 1
- X product description
- Fig 2 4 design and components of the daikin altherma ehs x h p50a external view and internal design for legend descriptions see tab 2 1
- Device external and internal design daikin altherma ehs x h p50a
- X product description
- Fig 2 5 design and components of the daikin altherma ehs x h b p50a external view and internal design for legend descriptions see tab 2 1
- Device external and internal design daikin altherma ehs x h b p50a
- X product description
- X set up and installation
- Set up and installation
- Dimensions and connections
- Daikin altherma ehs x h p30a
- Daikin altherma ehs x h p50a
- X set up and installation
- Scope of delivery
- X set up and installation
- Set up
- X set up and installation
- Water connection
- X set up and installation
- Electrical connection
- Connecting hydraulic lines
- X set up and installation
- Overall connection plan daikin altherma ehs x h
- Fig 3 7 overall connection diagram for electrical connection during device installation
- Explanation of symbols and abbreviations in this chap ter see tab 3 2 and tab 3 3
- The a1p circuit board comes pre connected to the unit no as sembly or connection work is necessary on the a1p circuit board
- Terminal assignment for the rtx ehs circuit board
- Terminal assignment for the rtx al4 circuit board
- Position of the circuit boards
- Connection assignment circuit board a1p
- X set up and installation
- X set up and installation
- Removing the protective cover
- Mains connection daikin altherma ehs x h
- Connection assignment circuit board rocon bm1
- X set up and installation
- Opening the control housing and establishing electrical connections
- Connection of external temperature sensor rocon ot1
- Connection of erlq exterior heat pump unit
- X set up and installation
- External demand signal eds
- Connection of an external switching contact
- Connection variant 2
- Connection variant 1
- Connection of the electrical daikin backup heater ekbuxx
- Connection of an external heat generator
- X set up and installation
- X set up and installation
- Caution
- X set up and installation
- Daikin room station ehs157034
- Daikin mixer module ehs157068
- Connection optional daikin rocon system components
- Connection of the daikin room thermostat
- X set up and installation
- Low tariff mains connection ht nt
- Internet gateway daikin ehs157056
- Connection switch contacts aux outputs
- Connection of the daikin fwxv 15 20 aveb
- C onnection of the daikin fwxv 15 20 aveb
- Symbols and legend keys on connection and circuit diagrams
- Connection intelligent controller smart grid sg
- X set up and installation
- X set up and installation
- X set up and installation
- Laying coolant lines
- X set up and installation
- Pressure test and filling the coolant circuit
- Filling the system with water
- Filling the storage tank
- Filling the hot water heat exchanger
- Filling the heating system
- Checking the water quality and adjusting the pressure gauge
- Start up
- Set the commissioning parameters
- Requirements
- L commissioning
- Initial commissioning
- X start up
- X start up
- Venting the internal heating circulation pump
- Expert
- X start up
- Start up
- Requirements
- Re commissioning
- Configuring screed program parameters only if necessary
- Check minimum flow
- Activating the parameter air purge
- X start up
- Without solar installation
- Temporary shutdown
- Draining the storage tank
- Decommissioning
- X decommissioning
- X decommissioning
- Only for the solar installation
- Draining the heating circuit and hot water circuit
- X decommissioning
- Recommendations for disposal
- Final shutdown
- X service and maintenance
- Service and maintenance
- Removing the protective cover
- Legal requirements
- General
- Activities to be performed annually
- X service and maintenance
- With kfe filling connection or with installed solar system see also chapter 5
- Filling and topping up the storage tank
- X service and maintenance
- Without installed solar system
- X service and maintenance
- Filling and topping up the heating system
- X errors malfunctions and messages
- Troubleshooting
- Recognising errors correcting malfunctions
- Read protocol
- Errors malfunctions and messages
- Current fault display
- X errors malfunctions and messages
- Malfunctions
- X errors malfunctions and messages
- X errors malfunctions and messages
- X errors malfunctions and messages
- Fault codes
- X errors malfunctions and messages
- X errors malfunctions and messages
- X errors malfunctions and messages
- X errors malfunctions and messages
- X errors malfunctions and messages
- X errors malfunctions and messages
- Touching live parts can result in an electric shock and lead to potentially fatal injuries and burns
- Pump continuous running off
- No designation factory setting
- Monitoring and configuration dip switch
- Domestic hot water gener ation on
- Do not change off
- Disconnect the system from the power supply open the control housing and remove the rocon bm1 board see chapter 3 check the dip switch setting on the a1p circuit board of the daikin altherma ehs x h adjust where necessary see tab 7 4 the factory preset may only be changed if e g an optional accessory was connected replace the rocon bm1 switch board close the control housing and reconnect the power supply
- Dip switch settings are not recognised until a brief inter ruption to the power supply
- Dip switch
- Before beginning work on live parts disconnect all of the systems circuits from the power supply switch off main switch disconnect fuse and secure against unintentional restart
- X errors malfunctions and messages
- Warning
- X errors malfunctions and messages
- Emergency operation
- X hydraulic system connection
- Hydraulic system connection
- X hydraulic system connection
- X hydraulic system connection
- X technical data
- Technical data
- Equipment data
- Daikin altherma ehs x h p30a
- X technical data
- X technical data
- Daikin altherma ehs x h p50a
- Characteristic lines
- X technical data
- Sensor characteristic lines
- X technical data
- Sensor resistance in ohm
- Sensor output frequency in hz
- Pt 1000
- Measured temperature in c
- Measured flow in l min
- M l min
- Fls sensor flow temperature
- 14 229 hz
- X technical data
- Tightening torque
- Characteristic curves for pumps
- Fig 9 8 circuit diagram daikin altherma ehs x h for legend see tab 3 3
- Circuit diagram daikin altherma ehs x h
- X technical data
- X notes
- X notes
- X list of keywords
- Numerics
- List of keywords
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
Подробное руководство по установке и обслуживанию тепловых насосов и солнечных систем. Узнайте о безопасности, подключениях и эксплуатации оборудования.